The use of microbolometers for Thermoelastic Stress Analysis (TSA) has the potential substantially reducing deployment costs, as well providing more compact and lightweight solutions in comparison to costly, bulky less rugged photon detector based infrared cameras. However, microbolometer performance terms response time sensitivity is than what can be achieved with detectors. As TSA becoming widespread, it timely devise a means assessing identifying limitations using such system TSA. A simulation approach devised that enables effect on transient signals (such from TSA) investigated. involves measuring small temperature change, usually induced by sinusoidal cyclic loading, also includes noisy non-sinusoidal signal. To identify any deleterious effects cause load, change generated an optical chopper black body source. variables studied are Signal-to-Noise Ratio (SNR), impact different waveforms, variation signal mean, in-built features noise reduction. new experimentally validated calibration presented accounts rolling averages introduced inbuilt reduction features. It shown independent specimen material camera frame rates, demonstrated CFRP test containing hidden crack.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermoelastic Stress Analysis for Linear Thermoelastic Bodies

The thermoelastic stress analysis for linear thermoelastic bodies is developed as a mathematical support to the infra-red radiometric method (SPATE) applied to structures under cyclic loading conditions.

متن کامل

A Review of Residual Stress Analysis using Thermoelastic Techniques

Thermoelastic Stress Analysis (TSA) is a full-field technique for experimental stress analysis that is based on infra-red thermography. The technique has proved to be extremely effective for studying elastic stress fields and is now well established. It is based on the measurement of the temperature change that occurs as a result of a stress change. As residual stress is essentially a mean stre...

متن کامل

Derivation of the stress concentrations at holes in orthotropic plates using thermoelastic stress analysis

An experimental study of the stress distribution around holes in orthotropic composite laminates has been conducted using thermoelastic stress analysis (TSA). Quantitative thermoelastic studies of stress concentrations in metallic plates is a straightforward matter, all that is required is the ratio of the response from the hole and a far-field reading. For orthotropic materials the situation i...

متن کامل

Thermoelastic investigation of residual stress: plastic deformation and the change in thermoelastic constant

Plastic deformation causes very small changes in the thermoelastic response of metallic materials; this variation of the thermoelastic constant has the potential to form the basis of a new non-destructive, non-contact, full-field technique for residual stress assessment that is quicker and cheaper than existing methods. The effect of plastic strain on the thermoelastic constant is presented as ...

متن کامل

Stress Analysis of Magneto Thermoelastic and Induction Magnetic Filed in FGM Hallow Sphere

In this paper a closed form solution for one-dimensional magnetothermoelastic problem in a functionally graded material (FGM) hollow sphere placed in a uniform magnetic field and temperature field subjected to an internal pressure is obtained using the theory of magnetothermoelasticity. Hyper-geometric functions are employed to solve the governing equation. The material properties through the g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Optics and Lasers in Engineering

سال: 2023

ISSN: ['1873-0302', '0143-8166']

DOI: https://doi.org/10.1016/j.optlaseng.2022.107276