Quantitative sodium imaging with a flexible twisted projection pulse sequence
نویسندگان
چکیده
منابع مشابه
SCALE PWI: A Pulse Sequence for Quantitative Cerebral Perfusion Imaging
INTRODUCTION Quantitative cerebral perfusion is a fundamental physiologic parameter that reflects the severity and progression of a broad range of pathologies including: cancer, stroke, Alzheimer’s Disease, and cerebrovascular occlusive disease. The “Bookend” technique [1,2] allows quantification of cerebral blood flow (CBF) and cerebral blood volume (CBV) with dynamic susceptibility contrast (...
متن کاملMeasuring human cardiac tissue sodium concentrations using surface coils, adiabatic excitation, and twisted projection imaging with minimal T2 losses.
PURPOSE To measure tissue sodium concentrations in the human heart with (23)Na MRI using a surface coil, thereby eliminating the effects of inhomogeneous excitation by surface coils and minimizing T(1) and T(2) relaxation. MATERIALS AND METHODS We combined fully relaxed, very short-echo, (23)Na twisted projection imaging (TPI) with adiabatic half passage (AHP) excitation and external referenc...
متن کاملQuantitative Imaging of Intracellular Sodium
A fundamental functional principle of animal cells is their ability to store energy across the plasma membrane in form of ion gradients. This is mainly realized by the activity of the Na/K-ATPase, which consumes ATP to establish an inwardly directed gradient for sodium ions. In the brain, the sodium gradient not only drives many transport processes across the plasma membrane, but also provides ...
متن کاملSCALE-PWI: A pulse sequence for absolute quantitative cerebral perfusion imaging.
The Bookend technique is a magnetic resonance imaging (MRI) dynamic susceptibility contrast method that provides reliable quantitative measurement of cerebral blood flow (CBF) and cerebral blood volume (CBV). The quantification is patient specific, is derived from a steady-state measurement of CBV, and is obtained from T(1) changes in the white matter and the blood pool after contrast agent inj...
متن کاملNew scheduling rules for a dynamic flexible flow line problem with sequence-dependent setup times
In the literature, the application of multi-objective dynamic scheduling problem and simple priority rules are widely studied. Although these rules are not efficient enough due to simplicity and lack of general insight, composite dispatching rules have a very suitable performance because they result from experiments. In this paper, a dynamic flexible flow line problem with sequence-dependent se...