Quantum Efficiency of Cold Electron Bolometer Optical Response
نویسندگان
چکیده
منابع مشابه
Concept of a mixer based on a cold-electron bolometer
Chalmers Publication Library (CPL) offers the possibility of retrieving research publications produced at Chalmers University of Technology. It covers all types of publications: articles, dissertations, licentiate theses, masters theses, conference papers, reports etc. Since 2006 it is the official tool for Chalmers official publication statistics. To ensure that Chalmers research results are d...
متن کاملA strained silicon cold electron bolometer using Schottky contacts
T. L. R. Brien, P. A. R. Ade, P. S. Barry, C. Dunscombe, D. R. Leadley, D. V. Morozov, M. Myronov, E. H. C. Parker, M. J. Prest, M. Prunnila, R. V. Sudiwala, T. E. Whall, and P. D. Mauskopf School of Physics and Astronomy, Cardiff University, Queen’s Buildings, The Parade, Cardiff CF24 3AA, United Kingdom Department of Physics, University of Warwick, Coventry CV4 7AL, United Kingdom VTT Technic...
متن کاملUltimate Cold-Electron Bolometer with Strong Electrothermal Feedback
ABSTRACT A novel concept of the Cold-Electron Bolometer (CEB) with strong electrothermal feedback has been proposed. The concept is based on direct electron cooling of the absorber that serves as negative electrothermal feedback for incoming signal. This feedback is analogous to TES (transition-edge sensor) but additional dc heating is replaced by deep electron cooling to minimum temperature. I...
متن کاملOptical Response of Strained- and Unstrained-Silicon Cold-Electron Bolometers
We describe the optical characterisation of two silicon cold-electron bolometers each consisting of a small (32 × 14 μm) island of degenerately doped siliconwith superconducting aluminium contacts. Radiation is coupled into the silicon absorber with a twin-slot antenna designed to couple to 160-GHz radiation through a silicon lens. Thefirst device has a highly doped silicon absorber, the second...
متن کاملdevelopment of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles
a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...
ذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Terahertz Science and Technology
سال: 2014
ISSN: 2156-342X,2156-3446
DOI: 10.1109/tthz.2014.2379331