QuickSite CRT Lead Conductor Externalization: A Short Story
نویسندگان
چکیده
منابع مشابه
Thrombus formation on a defibrillator lead with conductor externalization
A 51 year old man with arrhythmogenic right ventricular cardiomyopathy reported non-specific symptoms of muscle aches and shivering at outpatient review. A dual chamber implantable cardioverter defibrillator (ICD) had been inserted seven years previously. Fluoroscopic lead screening had previously demonstrated conductor externalisation (Figure and Video) of a single coil Riata ICD lead (model n...
متن کاملExternalized Conductor Cables in QuickSite Left Ventricular Pacing Lead and Riata Right Ventricular Lead in a Single Patient: A Common Problem With Silicone Insulation
QuickSite (St Jude Medical, Sylmar, CA, USA) is a silicone and polyurethane-insulated coronary sinus pacing lead. Riata lead (St Jude Medical, Sylmar, CA, USA) is a silicone insulated right ventricular shock lead. Recently, insulation breach of silicone based leads raised a huge concern. Fluoroscopic examination of these two leads in the same patient revealed externalization of these two leads....
متن کاملfeatures of short story in translated and non-translated literature: a polysystemic perspective
ترجمه متون ادبی در دنیای امروز از اهمیت ویژه ای برخوردار است. فرهنگ های مختلف با استفاده از متون ادبی ملل و فرهنگ های دیگر سعی در غنی کردن فرهنگ و ادبیات کشور خود دارند. کشور ما نیز از این قاعده مستثنی نیست. در ایران، ترجمه متون ادبی اروپائی که با دوران مشروطه ایرانی آغاز می شود موجب تغییرات اساسی در فرهنگ، شیوه زندگی و تفکر ایرانیان شده است. در این دوران نه تنها در امورات سیاسی و فکری کشور تغی...
15 صفحه اولRadiographic predictors of lead conductor fracture.
BACKGROUND Lead fracture is a limiting factor in high voltage lead durability. Fractures noted with the Medtronic Fidelis leads provide an opportunity to examine factors captured on implant chest x-ray that correlate with risk for lead conductor fracture. We evaluated contributory factors in a large population of fractures. METHODS AND RESULTS We conducted a retrospective case-control study a...
متن کاملA case of Durata ICD lead coil externalization: Inside-out lead abrasion?
The St Jude Medical Durata lead was produced in response to the recalled Riata and Riata ST leads in November 2011 after concerns of lead durability and inside-out abrasion. In order to protect against this susceptibility, the Riata ST Optim and Durata leads were coated with an abrasionresistant layer of silicone–polyurethane copolymer (Optim) tubing. We report a case of Durata lead extraction ...