QuickSite CRT Lead Conductor Externalization: A Short Story

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thrombus formation on a defibrillator lead with conductor externalization

A 51 year old man with arrhythmogenic right ventricular cardiomyopathy reported non-specific symptoms of muscle aches and shivering at outpatient review. A dual chamber implantable cardioverter defibrillator (ICD) had been inserted seven years previously. Fluoroscopic lead screening had previously demonstrated conductor externalisation (Figure and Video) of a single coil Riata ICD lead (model n...

متن کامل

Externalized Conductor Cables in QuickSite Left Ventricular Pacing Lead and Riata Right Ventricular Lead in a Single Patient: A Common Problem With Silicone Insulation

QuickSite (St Jude Medical, Sylmar, CA, USA) is a silicone and polyurethane-insulated coronary sinus pacing lead. Riata lead (St Jude Medical, Sylmar, CA, USA) is a silicone insulated right ventricular shock lead. Recently, insulation breach of silicone based leads raised a huge concern. Fluoroscopic examination of these two leads in the same patient revealed externalization of these two leads....

متن کامل

features of short story in translated and non-translated literature: a polysystemic perspective

ترجمه متون ادبی در دنیای امروز از اهمیت ویژه ای برخوردار است. فرهنگ های مختلف با استفاده از متون ادبی ملل و فرهنگ های دیگر سعی در غنی کردن فرهنگ و ادبیات کشور خود دارند. کشور ما نیز از این قاعده مستثنی نیست. در ایران، ترجمه متون ادبی اروپائی که با دوران مشروطه ایرانی آغاز می شود موجب تغییرات اساسی در فرهنگ، شیوه زندگی و تفکر ایرانیان شده است. در این دوران نه تنها در امورات سیاسی و فکری کشور تغی...

15 صفحه اول

Radiographic predictors of lead conductor fracture.

BACKGROUND Lead fracture is a limiting factor in high voltage lead durability. Fractures noted with the Medtronic Fidelis leads provide an opportunity to examine factors captured on implant chest x-ray that correlate with risk for lead conductor fracture. We evaluated contributory factors in a large population of fractures. METHODS AND RESULTS We conducted a retrospective case-control study a...

متن کامل

A case of Durata ICD lead coil externalization: Inside-out lead abrasion?

The St Jude Medical Durata lead was produced in response to the recalled Riata and Riata ST leads in November 2011 after concerns of lead durability and inside-out abrasion. In order to protect against this susceptibility, the Riata ST Optim and Durata leads were coated with an abrasionresistant layer of silicone–polyurethane copolymer (Optim) tubing. We report a case of Durata lead extraction ...

متن کامل