Quo vadishigh-resolution continuum source atomic/molecular absorption spectrometry?
نویسندگان
چکیده
منابع مشابه
Molecule formation mechanisms of strontium mono fluoride in high-resolution continuum source electrothermal atomic absorption spectrometry.
In this study, the molecule formation mechanisms of strontium mono fluoride used for the determination of fluorine in a high-resolution continuum source atomic absorption spectrophotometer was investigated. To distinguish between the gas-phase and the condensed-phase mechanisms, the analyte (F) and the molecule forming element (Sr) were injected on the solid sampling platform manually, as mixed...
متن کاملHigh - Resolution Continuum - source Atomic Absorption Spectrometry – What Can We Expect ?
Um novo conceito instrumental vem sendo desenvolvido para espectrometria de absorção atômica (AAS), usando como fonte de radiação uma lâmpada de xenônio de alta intensidade, um monocromador double-echelle e um dispositivo com arranjo de carga acoplada como detector, permitindo uma resolução de ~2 pm por pixel. Entre as principais vantagens do sistema estão: i) uma melhora na razão sinal/ruído d...
متن کاملDetermination of Gold by High-Resolution Continuum Source Atomic Absorption Spectrometry with Chemical Vapor Generation
Avaliou-se o potencial analítico da geração de vapor químico e da espectrometria de absorção atômica com fonte contínua de alta resolução com atomização em tubo de quartzo na determinação de ouro. As espécies voláteis de ouro foram formadas pela reação com tetraidroborato(III) de sódio na presença de ácido clorídrico. Investigou-se a influência de brometo de didodecil dimetilamônio (DDAB) e die...
متن کاملDetermination of Copper at Wide Range Concentrations Using Instrumental Features of High-resolution Continuum Source Flame Atomic Absorption Spectrometry
This work describes a method to determine Cu at wide range concentrations in a single run without need of further dilutions employing high-resolution continuum source flame atomic absorption spectrometry. Different atomic lines for Cu at 324.754 nm, 327.396 nm, 222.570 nm, 249.215 nm and 224.426 nm were evaluated and main figures of merit established. Absorbance measurements at 324.754 nm, 249....
متن کاملDetermination of Lead in Eye Shadow and Blush by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry Employing Direct Solid Sampling
A espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua (HR-CS GF AAS) é proposta para determinar Pb em sombra de olho e blush empregando a análise direta de sólidos. O emprego da mistura de modificadores químicos Pd(NO3)2 + Mg(NO3)2 possibilitou a calibração aquosa de 0,25 a 2,5 ng Pb (r = 0,998). O desempenho do método proposto foi avaliado por meio da an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Analytical Atomic Spectrometry
سال: 2019
ISSN: 0267-9477,1364-5544
DOI: 10.1039/c8ja00256h