Radial Nerve F-wave reference values with surface electrodes from the anconeus muscle
نویسندگان
چکیده
منابع مشابه
Effect of height on F-wave latency: Redefining reference values for Iranian population
Intrudaction: F-wave latency is one of the most sensitive parameters which is used for diagnosis of radiculopathy and neuropathy in electrodiagnostic medicine. Electrodianosis professionals mostly use reference values published in major textbooks mostly written in USA based on anthropomorphic characteristics of American people. Also there is considerable difference between heights of males an...
متن کاملDorsal ulnar cutaneous nerve conduction: reference values.
We investigated the reference values of the dorsal ulnar cutaneous nerve (DUC) sensory nerve conduction (SNC) in 66 healthy individuals. Measurements were processed using stimulating electrodes positioned between the ulnar bone and the flexor carpi ulnaris muscle, 11-13 cm proximal to the active electrode recording. Superficial recording electrodes were placed on the fourth intermetacarpal spac...
متن کاملUlnar nerve palsy due to concomitant compression by the anconeus epitrochlearis muscle and a ganglion cyst.
Compression neuropathy of the ulnar nerve at the elbow is commonly caused by constriction at the fibrous cubital tunnel or an anatomical elbow deformity. Many uncommon causes of compression have been described, including Osborne’s band, ulnar nerve subluxation,1 anatomical confines of the cubital tunnel, elbow osteoarthritis, ganglion,2 prominent medial head of triceps,3 and an anconeus epitroc...
متن کاملReference values for isometric muscle force among workers for the Netherlands: a comparison of reference values
BACKGROUND Muscle force is important for daily life and sports and can be measured with a handheld dynamometer. Reference values are employed to quantify a subject's muscle force. It is not unambiguous whether reference values can be generalized to other populations. Objectives in this study were; first to confirm the reliability of the utilization of hand-held dynamometers for isometric streng...
متن کاملReference values for the arterial pulse wave in Chinese.
BACKGROUND Pulse wave analysis using the SphygmoCor system allows the estimation of central pulse pressure (PP) and peripheral and central augmentation indexes (AIxs). We studied the limits of normality of these measurements in Chinese. METHODS We computed limits of normality as the 95% confidence boundaries from regression models relating the arterial indexes to age. RESULTS The reference ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Muscle & Nerve
سال: 2018
ISSN: 0148-639X
DOI: 10.1002/mus.26351