Radial trunk-centred reference frame in haptic perception
نویسندگان
چکیده
منابع مشابه
Egocentric reference frame bias in the palmar haptic perception of surface orientation.
The effect of egocentric reference frames on palmar haptic perception of orientation was investigated in vertically separated locations in a sagittal plane. Reference stimuli to be haptically matched were presented either haptically (to the contralateral hand) or visually. As in prior investigations of haptic orientation perception, a strong egocentric bias was found, such that haptic orientati...
متن کاملReference frame and haptic discrimination of orientations in infants.
Body-tilt effect on the haptic discrimination of orientations and the 'oblique effect' (better discrimination of the vertical orientation than of an oblique orientation) were examined in 5-month-old infants. Body tilt leads to a mismatch between egocentric and gravitational reference frames and indicates in which reference frame orientations and oblique effect are defined. A familiarization/rea...
متن کاملHaptic mental rotation revisited: multiple reference frame dependence.
The nature of reference frames involved in haptic spatial processing was addressed by means of a haptic mental rotation task. Participants assessed the parity of two objects located in various spatial locations by exploring them with different hand orientations. The resulting response times were fitted with a triangle wave function. Phase shifts were found to depend on the relation between the ...
متن کاملAllocentrically implied target locations are updated in an eye-centred reference frame.
When reaching to remembered target locations following an intervening eye movement a systematic pattern of error is found indicating eye-centred updating of visuospatial memory. Here we investigated if implicit targets, defined only by allocentric visual cues, are also updated in an eye-centred reference frame as explicit targets are. Participants viewed vertical bars separated by varying dista...
متن کاملCan axes conventions of the trunk reference frame influence breast displacement calculation during running?
To obtain breast motion relative to the trunk, skin markers are used to define a local coordinate system (trunk), with respect to the global reference frame. This study aimed to quantify any differences in multiplanar breast displacement relative to the trunk using the first axis of rotation as either the mediolateral or longitudinal axis. Ten female participants ran on a treadmill (10 kph) in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Scientific Reports
سال: 2018
ISSN: 2045-2322
DOI: 10.1038/s41598-018-32002-3