Radiation dose in vertebroplasty
نویسندگان
چکیده
منابع مشابه
Significantly reduced radiation dose to operators during percutaneous vertebroplasty using a new cement delivery device
BACKGROUND Percutaneous vertebroplasy (PVP) might lead to significant radiation exposure to patients, operators, and operating room personnel. Therefore, radiaton exposure is a concern. The aim of this study was to present a remote control cement delivery device and study whether it can reduce dose exposue to operators. METHODS After meticulous preoperative preparation, a series of 40 osteopo...
متن کاملRadiation Dose Reduction Techniques in the Workplace
The principal objective of radiation protection is to ensure that the dose received by any individual does not exceed the applicable M.P.D. values.We will discuss in this paper the presents recommendations and technical information related to the design and installation of structural shielding with taking into account the concept of Maximum Permissible Dose equivalent (MPDl as expressed and ...
متن کاملDoes Vertebroplasty Affect Radiation Dose Distribution?: Comparison of Spatial Dose Distributions in a Cement-Injected Vertebra as Calculated by Treatment Planning System and Actual Spatial Dose Distribution
Purpose. To assess differences in dose distribution of a vertebral body injected with bone cement as calculated by radiation treatment planning system (RTPS) and actual dose distribution. Methods. We prepared two water-equivalent phantoms with cement, and the other two phantoms without cement. The bulk density of the bone cement was imported into RTPS to reduce error from high CT values. A dose...
متن کاملOptimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality
Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...
متن کاملAssessment of radiation dose in nuclear medicine hot lab
Background: Hot lab is a specially designed room in a nuclear medicine hospital where the radiopharmaceuticals are delivered, stored and prepared for dispensing. 99Mo/99mTc-generator is the major source in the hot lab used for various medical imaging. It is important to maintain a standard for hot lab procedures to optimize the patient care and minimize radiation exposure to all nuclear medicin...