Radiation hardness of silicon detectors manufactured on wafers from various sources

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aspects of radiation hardness for silicon microstrip detectors

The ways in which radiation damage affects the properties of silicon microstrip detectors are reviewed and discussed in the context of inner tracking or vertexing requirements for the LHC experiments.

متن کامل

Radiation Hardness of Silicon Detectors - A Challenge from High Energy Physics

An overview of the radiation damage induced problems connected with the application of silicon particle detectors in future high energy physics experiments is given. Problems arising from the expected hadron fluences are summarized and the use of the nonionizing energy loss for normalization of bulk damage is explained. The present knowledge on the deterioration effects caused by irradiation is...

متن کامل

Electromagnetic Radiation Hardness of Diamond Detectors

The behavior of artificially grown CVD diamond films under intense electromagnetic radiation has been studied. The properties of irradiated diamond samples have been investigated using the method of thermally stimulated current and by studying their charge collection properties. Diamonds have been found to remain unaffected after doses of 6.8 MGy of 10 keV photons and 10 MGy of MeV-range photon...

متن کامل

Looking at trace impurities on silicon wafers with synchrotron radiation.

Figure 1. TXRF spectrum of a clean Si wafer surface showing 6.4x10 atoms/cm Fe and 2.6x10 atoms/cm Cu. The Cl is a residue from the HCl solution used to clean the wafer surface and the Ag is a artifact from the particular collimator used in these studies. Other features seen in the spectrum are the Si substrate peak, the scatter peak at 11.2 keV and the escape peak at 9.4 keV. Looking at Trace ...

متن کامل

Does Radiation Improve Silicon Detectors?

Sensors designed for the CMS Preshower detector were irradiated with protons and neutrons to fluences equivalent up to 2x10 n/cm. The leakage current and the capacitance as well as the charge collection efficiency and the noise were measured, before and after the irradiation, for most of the detectors. We noticed, that for some detectors of a lower quality, the breakdown voltage increases after...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

سال: 1997

ISSN: 0168-9002

DOI: 10.1016/s0168-9002(97)00005-3