Radiological Evaluation of Uncinate Process Variations using Multidetector Computed Tomography
نویسندگان
چکیده
Introduction: Functional endoscopic sinus surgery has emerged as a superior technique in with lower incidence of associated complications compared to traditional surgeries; however, it still carries risks possible complications, some which could be attributable the variations that exist nose and paranasal anatomy. Variations uncinate process, one important structural landmarks functional can have implications during surgery. Therefore, identifying process becomes very consideration. The objective this study was identify on Multidetector Computed Tomography sinuses
 Methods: This cross-sectional conducted Department Radiodiagnosis, Birat Medical College Teaching from December 2021 June 2022 after obtaining ethical clearance IRC. A total 240 participants referred Radiodiagnosis for CT sinuses were included study.
 Results: most frequent attachment found Type I least common IV. variation UP pneumatisation. Most cases showed typical angulation followed by medial orientation lateral orientation.
 Conclusion: is commendable tool these variations.
منابع مشابه
Tracheobronchial variations evaluated by multidetector computed tomography and virtual bronchoscopy
Abstract Introduction The tracheobronchial tree exhibits a wide range of variations. The purpose of this study is the investigation of the frequency and multidetector tomographic (MDCT) findings of anatomical variations of the main bronchi and of the lobar bronchi, as well as the detection of abnormal bronchi originated from the trachea, in subjects without severe bronchial pathology. Materials...
متن کاملMultiple renal arteries: variations demonstrated by multidetector computed tomography angiography.
OBJECTIVE To present a case of a rare variation of the renal artery and multiple (7) renal arteries by multidetector computed tomography (MDCT) angiography. CLINICAL PRESENTATION AND INTERVENTION A 36-year-old male patient was admitted to our hospital as a potential living donor for renal transplantation. An MDCT angiography was performed using a 16-detector row CT scanner to obtain a detaile...
متن کاملSinonasal Anatomical Variations: A Multidetector Computed Tomographic Study
Background and Aim: The paranasal sinuses are known for their complex anatomy and significant difference in size and shape. This study aimed to determine the prevalence of anatomical variations of the paranasal sinuses in computed tomography (CT). Materials and Methods: In this cross-sectional study, patients over 18 years of age, who had undergone CT imaging in a private clinic, were screened...
متن کاملMultidetector Computed Tomography Evaluation of Subtypes of Renal Cell Carcinoma
Early mortality of most of the (40%) of patients with RCC is because of the disease progression, advanced stage at presentation, and delayed diagnosis. Thus, this tumor is the most lethal malignant urological tumor. The histological classification of RCCs is extremely important, due to implications of the subtypes in the prognosis and treatment of these tumors.3,4 In this context, a pre-operati...
متن کاملEvaluation of neurovascular anatomical variations in maxillary anterior region in cone beam computed tomography images
Introduction: Incisive foramen in the maxilla is the oral terminus of the nasopalatine canal. This region is important in implantology, Therefore, the aim of this study was to investigate the neurovascular anatomical variations in the maxillary anterior region, observed on cone beam computed tomography (CBCT) images. Materials &Methods: In this cross-sectional study, maxillary CBCT ima...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nepal Journal of Medical Sciences
سال: 2023
ISSN: ['2091-1459', '2091-1424']
DOI: https://doi.org/10.3126/njms.v8i1.54305