RAPID INTRARENAL CIRCULATION
نویسندگان
چکیده
منابع مشابه
Microsphere measurement of intrarenal circulation of the dog.
Distribution of cortical blood flow was measured in the dog by a technique based on radionuclide-labeled microspheres. Initially it was necessary to test possible pitfalls of this technique. Completeness of trapping in the kidney, the effect on renal function, and the notion that microsphere distribution reflects blood flow distribution in the kidney cortex were studied. Renal vein blood contai...
متن کاملIntrarenal reflux
A 5-year-old girl was admitted with fever and diurnal enuresis. In her medical history, she had numerous recurrent urinary tract infections; however, she was not evaluated with radiological methods. Urinalysis revealed pyuria and the urine culture grew >100 000 Escherichia coli. Urinary ultrasonography showed that the left kidney was smaller than the right kidney, with a longitudinal kidney dia...
متن کاملRAPID TRANSITIONS OF THE THERMOHALINE OCEAN CIRCULATION A Modelling Perspective
This chapter discusses the stability of the Atlantic thermohaline circulation with special emphasis on the critical thresholds and state transitions found in model experiments. The thermohaline ocean circulation is a major heat transport mechanism which causes the relatively mild climate in the North Atlantic region (including Europe) in the modern times. The formation of North Atlantic Deep Wa...
متن کاملRapid adaptation of the intrarenal resistance index after living donor kidney transplantation.
BACKGROUND Limited data exist concerning changes of renal perfusion directly after kidney transplantation. Colour-coded duplex sonography is the accepted method to assess kidney perfusion after transplantation. A widely used, although unspecific, Doppler parameter is the intrarenal resistance index (RI). The aim of this study was to clarify the influence of different patient- and procedure-rela...
متن کاملA Method for Rapid Measurement of Intrarenal and Other Tissue Pressures
A rapid method for measuring tissue pressures has been designed. A pressure of 250 mm. Hg is imposed on a manometer. Then the system is allowed to discharge into a needle cannula inserted in the tissue. The manometer forces out fluid (about 10 c.mm.) until the pressure within it is the same as that within the tissue. Records of the pressure changes are made. Each observation takes about a minut...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: American Journal of Roentgenology
سال: 1970
ISSN: 0361-803X,1546-3141
DOI: 10.2214/ajr.109.1.167