Rapid method for deblurring spiral MR images
نویسندگان
چکیده
منابع مشابه
Universal deblurring method for real images using transition region
Tianxu Zhang Huazhong University of Science and Technology Institute for Pattern Recognition and AI Wuhan, 430074, China Abstract. In this paper, we present a universal deblurring method for real images without prior knowledge of the blur source. The proposed method uses the transition region of the blurred image to estimate the point spread function (PSF). It determines the main edges of the b...
متن کاملAn Enhanced Median Filter for Removing Noise from MR Images
In this paper, a novel decision based median (DBM) filter for enhancing MR images has been proposed. The method is based on eliminating impulse noise from MR images. A median-based method to remove impulse noise from digital MR images has been developed. Each pixel is leveled from black to white like gray-level. The method is adjusted in order to decide whether the median operation can be appli...
متن کاملDeblurring in AFM images
Atomic Force Microscopy (AFM) has been widely used in the material and life sciences and has enabled much progress in nanotechnology since it was invented. AFM relies on inter-atomic forces to form a topographical map of a sample surface. Depending on the surface type, it is possible to achieve atomic resolution. However, due to either the microscope design and operation mode or external enviro...
متن کاملBlock regional off-resonance correction (BRORC): a fast and effective deblurring method for spiral imaging.
One primary disadvantage of spiral imaging is blurring artifact due to off-resonance effects. The conventional frequency segmented off-resonance correction method that is performed over the entire image is computationally intense due to the large number of fast Fourier transforms (FFTs) required. Here, a new fast off-resonance correction method, block regional off-resonance correction (BRORC), ...
متن کاملBlind deblurring of spiral CT images-comparative studies on edge-to-noise ratios.
A recently developed blind deblurring algorithm based on the edge-to-noise ratio has been applied to improve the quality of spiral CT images. Since the discrepancy measure used to quantify the edge and noise effects is not symmetric, there are several ways to formulate the edge-to-noise ratio. This article is to investigate the performance of those ratios with phantom and patient data. In the p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Magnetic Resonance in Medicine
سال: 2000
ISSN: 0740-3194,1522-2594
DOI: 10.1002/1522-2594(200009)44:3<491::aid-mrm22>3.0.co;2-z