Rapid method to determine 226Ra in steel samples

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An emergency radiobioassay method for 226Ra in human urine samples.

A new radioanalytical method was developed for rapid determination of (226)Ra in human urine samples. The method is based on organic removal and decolourisation of a urine sample by a polymeric (acrylic ester) solid phase sorbent material followed by extraction and preconcentration of (226)Ra in an organic solvent using a dispersive liquid-liquid microextraction technique. Radiometric measureme...

متن کامل

Rapid method to determine labeling specificity of radioactive enteroviruses.

The specificity of labeling enteroviruses with (32)P-labeled NaH(2)PO(4) or (14)C-leucine can be determined by comparing the percent adsorption of infective particles and radioactivity to membrane (Millipore) filters.

متن کامل

Comparison PCR Method and Rapid Urease Test to Detect Helicobacter Pylori in the Gastric Biopsy Tissue Samples

Background & Objective: Helicobacter pylori has been recognized as a major risk factor in gastric and duodenum ulcers and gastric cancer. Some laboratory tests, such as culture, are not entirely satisfying. The aim of this study is to compare RUT with PCR in identifying H. pylori in the gastric biopsy tissue samples.Materials & Methods: First, the standard H.pylori sample (N:oC30) was provided....

متن کامل

Application of Dispersive Liquid-Liquid Microextraction to Determine Aflatoxin B1 in Tomato Paste Samples

Background: Aflatoxin B1 is a secondary toxic metabolite produced by several aspergillus species. This study was conducted to determine the presence of aflatoxin in tomato paste samples. Methods: A total of 30 tomato pastes were analyzed for Aflatoxin B1 contamination via HPLC-FLD. Analyte extraction was done by dispersive liquid-liquid microextraction. Results: The limit of detection (LOD) and...

متن کامل

DMOF-1 Assessment and Preparation to Electrochemically Determine Hydrazine in Different Water Samples

Hydrazine has been identified as a carcinogenic mutagenic, hepatotoxic, and neurotoxin material. A metal-organic framework with tetragonal symmetry, DMOF-1 (Zn2(bdc)2dabco) was synthesized by a versatile and facile technique, followed by its efficient development and validation as hydrazine electrochemical sensor. Differential pulse voltammetry (DPV), linear sweep voltammetry (LSV), and c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Radioanalytical and Nuclear Chemistry

سال: 2017

ISSN: 0236-5731,1588-2780

DOI: 10.1007/s10967-017-5491-8