Rat Head Phantom for Testing of Electroencephalogram Source Localization Techniques

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of inverse methods and head models for EEG source localization using a human skull phantom.

We used a real-skull phantom head to investigate the performances of representative methods for EEG source localization when considering various head models. We describe several experiments using a montage with current sources located at multiple positions and orientations inside a human skull filled with a conductive medium. The robustness of selected methods based on distributed source models...

متن کامل

Dipole Source Localization of Mouse Electroencephalogram Using the Fieldtrip Toolbox

The mouse model is an important research tool in neurosciences to examine brain function and diseases with genetic perturbation in different brain regions. However, the limited techniques to map activated brain regions under specific experimental manipulations has been a drawback of the mouse model compared to human functional brain mapping. Here, we present a functional brain mapping method fo...

متن کامل

Cortical Source Localization 1 Running Head: Infant Cortical Source Localization Cortical Source Localization of Infant Cognition

Neuroimaging techniques such as positron emission topography (PET) and functional magnetic resonance imaging (fMRI) have been utilized with older children and adults to identify cortical sources of perceptual and cognitive processes. However, due to practical and ethical concerns, these techniques cannot be routinely applied to infant participants. An alternative to such neuroimaging techniques...

متن کامل

Alzheimer ’ s Electroencephalogram Event Scalp and Source Localization

Alzheimer’s disease is the most common cause of dementia which causes a progressive and irreversible impairment of several cognitive functions. The aging population has been increasing significantly in recent decades and this disease affects mainly the elderly. Its diagnostic accuracy is relatively low and there is not a biomarker able to detect AD without invasive tests. Despite the progress i...

متن کامل

Randomized group testing for acoustic source localization

Undersea localization requires a computationally expensive partial differential equation simulation to test each candidate hypothesis location via matched filter. We propose a method of batch testing that effectively yields a test sequence output of random combinations of location-specific matched filter correlations, such that the computational run time varies with the number of tests instead ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Access

سال: 2020

ISSN: 2169-3536