Active Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads
Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...
متن کاملactive filter control method based on direct power control for compensating reactive powers due to unbalanced voltages and nonlinear loads
active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. this paper proposes a control scheme based on the instantaneous active and reactive power. the inverter of this active filter is a three-phase, two-level converter. space vector technique is used as modulators and pattern genera...
متن کاملA New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)
This paper presents a new control method for simultaneous compensation of instantaneous reactive power and current harmonics by parallel active filters (PAFs). Reference compensating currents of PAF are calculated using the subtraction of instantaneous power from its average value. In this way, it is possible omitting high/low pass filter(s) from the control circuit of PAF, which usually result...
متن کاملReactive power compensation for linear and non linear loads by using active and passive filter for smart grid applications
In this work a new control strategy for simulation of three phase power filter for power quality improvement is used .This filter consists of shunt passive LC power filter and series active filter, with nonlinear and linear loads and also with variation in the source impedance. A new control method based on dual formulation of instantaneous reactive power vectorial theory is applied by consider...
متن کاملA Simple Control Algorithm for Three-Phase Shunt Active Power Filter for Reactive Power and Current Harmonic Compensation
Power quality issues are becoming a major concern of today's power system engineers. Shunt active power filter (SAPF) is one of the effective means for harmonic current compensation in electrical power system. The performance and dynamic characteristics of a three-phase SAPF with a simple control algorithm is presented and analyzed in this paper. This algorithm operates at fixed switching frequ...