Reactive power compensation method in modern power system facing energy conversion
نویسندگان
چکیده
The equivalent model of modern power system is more and difficult to describe its complex stability characteristics, with the continuous promotion conversion. This paper proposes an improved method consider voltage deviation between side load side. On this basis, margin index derived. Therefore, relationship reactive compensation can be analyzed. Finally, correctness effectiveness are verified by IEEE39 node actual provincial grid. proposed obviously improve when applied small summer mode system. (The weakest increased 12.8%, average whole network 1.5%.)
منابع مشابه
Simulation of Power System Response To Reactive Power Compensation
I am submitting herewith a thesis written by Pierre Alexandre Bohême entitled " Simulation of Power System Response to Reactive Power Compensation. " I have examined the final electronic copy of this thesis for form and content and recommend that it be accepted in partial fulfillment of the requirements for the degree of Master of Science, with a major in Electrical Engineering. (Original signa...
متن کاملImprovement of perturb and observe method for maximum power point tracking in wind energy conversion system using fuzzy controller
One of the main problems in wind energy conversion system (WECS) is how to achieve maximum output power in different wind speeds. Maximum methods for maximum power point tracking in wind energy conversion systems require the knowledge of system characteristics and mechanic sensors. So, using these methods practically will follow with high price and an abundant difficulties. In this pape...
متن کاملImprovement of perturb and observe method for maximum power point tracking in wind energy conversion system using fuzzy controller
One of the main problems in wind energy conversion system (WECS) is how to achieve maximum output power in different wind speeds. Maximum methods for maximum power point tracking in wind energy conversion systems require the knowledge of system characteristics and mechanic sensors. So, using these methods practically will follow with high price and an abundant difficulties. In this pape...
متن کاملFuzzy Decision Method Applied in Action of Reactive Power Compensation Devices in Wind System
Frequent occurrence of large-scale cascading trip-off of wind turbine raises the concern about the decision process of ordered control of reactive power compensation devices. The theory of fuzzy multi-attribute decision making is adopted to ascertain the action sequence of reactive power compensation devices. First, a set of evaluation indexes including control sensitivity, regulation margin, r...
متن کاملDynamic compensation of reactive power in Various Faults in Power System
The STATCOM (Synchronous Static Compensator) based on voltage source converter (VSC) is used for voltage regulation in transmission and distribution system. The STATCOM can rapidly supply dynamic VARs required during system faults for voltage support. Strict requirements of STATCOM losses and total system loss penalty preclude the use of PWM (Pulse-Width Modulation) for VSC based STATCOM applic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Iet Generation Transmission & Distribution
سال: 2022
ISSN: ['1751-8687', '1751-8695']
DOI: https://doi.org/10.1049/gtd2.12374