Real-time blood flow imaging using autocalibrated spiral sensitivity encoding

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-time blood flow imaging using autocalibrated spiral sensitivity encoding.

A novel spiral phase contrast (PC) technique was developed for high temporal resolution imaging of blood flow without cardiac gating. An autocalibrated spiral sensitivity encoding (SENSE) method is introduced and used to reconstruct PC images. Numerical simulations and a flow phantom study were performed to validate the technique. To study the accuracy of the flow measurement in vivo, a high-re...

متن کامل

Through-Time Spiral GRAPPA for Real-Time Cardiac Imaging

Introduction: Accelerated data acquisition followed by parallel imaging reconstruction has been used in cardiac imaging to reduce imaging times and avoid artifacts due to motion. Coupled with non-Cartesian trajectories, such parallel imaging techniques can yield images with high acceleration factors with little residual aliasing. Recently, a method has been proposed which improves the radial GR...

متن کامل

Blood Vessel Contrast Enhancement Using Phase Corrected Real Imaging in Flow-sensitive Black Blood Imaging

Introduction A flow-sensitive black-blood imaging (FSBB) technique was proposed, where small motion probing gradients (MPG) of bfactor=2~4 [sec/mm] were combined with a 3D gradient-echo (GRE) sequence [1]. The FSBB technique was demonstrated to enhance slow flow vessels, such as collateral vessels [2], perforating veins [3], vascular malformations [4]. Simple magnitude images provided sufficien...

متن کامل

Variable-density Spiral Imaging for Real-time Color Flow Cardiac Mri at 3t

Introduction The ability of MRI to quantify blood flow with high spatial and temporal resolution has made it a promising technique for accurate blood flow mapping in-vivo. Nayak et al. have performed the real-time color flow MRI [1] in 1.5T systems. In this work real-time color flow MRI is developed on a 3T system based on a spiral phase contrast pulse sequence and real-time reconstruction. Two...

متن کامل

Real-time blood flow visualization using the graphics processing unit.

Laser speckle imaging (LSI) is a technique in which coherent light incident on a surface produces a reflected speckle pattern that is related to the underlying movement of optical scatterers, such as red blood cells, indicating blood flow. Image-processing algorithms can be applied to produce speckle flow index (SFI) maps of relative blood flow. We present a novel algorithm that employs the NVI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2005

ISSN: 0740-3194,1522-2594

DOI: 10.1002/mrm.20690