Real-Time Imaging of HIF-1α Stabilization and Degradation

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-Time Imaging of HIF-1α Stabilization and Degradation

HIF-1alpha is overexpressed in many human cancers compared to normal tissues due to the interaction of a multiplicity of factors and pathways that reflect specific genetic alterations and extracellular stimuli. We developed two HIF-1alpha chimeric reporter systems, HIF-1alpha/FLuc and HIF-1alpha(DeltaODDD)/FLuc, to investigate the tightly controlled level of HIF-1alpha protein in normal (NIH3T3...

متن کامل

Glucocorticoids promote Von Hippel Lindau degradation and Hif-1α stabilization.

Glucocorticoid (GC) and hypoxic transcriptional responses play a central role in tissue homeostasis and regulate the cellular response to stress and inflammation, highlighting the potential for cross-talk between these two signaling pathways. We present results from an unbiased in vivo chemical screen in zebrafish that identifies GCs as activators of hypoxia-inducible factors (HIFs) in the live...

متن کامل

NQO1 inhibits proteasome-mediated degradation of HIF-1α

Overexpression of NQO1 is associated with poor prognosis in human cancers including breast, colon, cervix, lung and pancreas. Yet, the molecular mechanisms underlying the pro-tumorigenic capacities of NQO1 have not been fully elucidated. Here we show a previously undescribed function for NQO1 in stabilizing HIF-1α, a master transcription factor of oxygen homeostasis that has been implicated in ...

متن کامل

HIF-1α antagonizes p53-mediated apoptosis by triggering HIPK2 degradation

Many human diseases are characterized by the development of tissue hypoxia. Hypoxia-inducible factor (HIF) is a transcription factor that regulates fundamental cellular processes in response to changes in oxygen concentration, such as angiogenesis, survival, and alterations in metabolism. The levels of HIF-1α subunit are increased in most solid tumors not only by low oxygen but also by growth f...

متن کامل

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: PLoS ONE

سال: 2009

ISSN: 1932-6203

DOI: 10.1371/journal.pone.0005077