Cystic duct variation detected by near-infrared fluorescent cholangiography during laparoscopic cholecystectomy
Near-infrared fluorescent cholangiography (NIRFC) is an emerging technique for easy intraoperative recognition of biliary anatomy. We present a case of cystic duct variation detected by NIRFC which had a potential risk for biliary injury if not detected. A 32-year-old female was admitted to the Seoul St. Mary's Hospital for surgery for an incidental gallbladder polyp. We performed laparoscopic ...
متن کاملAn Overview of Near Infrared Fluorescent Cholangiography with Indocyanine Green during Cholecystectomy
Laparoscopic cholecystectomy (LC) is one of the most common surgical procedures performed globally but continues to carry to an unacceptably high risk of iatrogenic bile duct injury (BDI). In recent years several centres have proposed Near Infrared Fluorescent Cholangiography (NIRFC) with Indocyanine Green (ICG) as a potential method of dynamic intraoperative extra hepatic bile duct mapping. We...
متن کاملSingle-Site Robotic Cholecystectomy
This study aims to introduce an alternative technique for effective single-site robotic cholecystectomy (SSRC) using a reverse port. Proper exposure of Calot’s triangle is critical for safe laparoscopic cholecystectomy. Current robotic surgical systems are useful for singlesite cholecystectomy. However, in exposing Calot’s triangle, the gallbladder is usually retracted in a medial and upward di...
متن کاملSingle-Site Robotic Cholecystectomy
BACKGROUND Laparoscopic single-incision surgery is fraught with significant technical drawbacks but has witnessed increased growth mainly for its presumed aesthetic advantages. Recently, a single-site robotic platform has been introduced to alleviate some of the technical challenges with laparoscopic single-site surgery, although literature on this topic is scant. The aim of this study is to an...
متن کاملIntraoperative near-infrared fluorescent imaging during robotic operations
The intraoperative identification of certain anatomical structures because they are small or visually occult may be challenging. The development of minimally invasive surgery brought additional difficulties to identify these structures due to the lack of complete tactile sensitivity. A number of different forms of intraoperative mapping have been tried. Recently, the near-infrared fluorescence ...