Real-Time Performance and Security of IEC 61850 Process Bus Communications

نویسندگان

چکیده

Modern power-network communications are based on the IEC 61850 series standards. In this paper, we investigate real-time performance and vulnerabilities attack scenarios at sensor level communication networks more precisely Sampled Measured Value protocol. The approach jointly evaluates protocol, network topology impact electrical protection functions. We test practical feasibility of attacks an experimental workbench using real devices in a hardware-in-the-loop setup. tests conducted two high-availability automation currently used process bus communications: Parallel Redundancy Protocol (PRP) High-availability Seamless (HSR)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

1 Performance Evaluation of IEC 61850 Process

The paper presents the performance of a novel distributed bus differential protection scheme, which utilizes independent multi-principle advanced protection algorithms, including differential percent slope, delta phase directional comparison, rate of change of differential (ROCOD) currents, delta phase directional comparison on neutral current differential, and a check zone to secure the electr...

متن کامل

Real Time Simulation Testing Using IEC 61850

-As IEC 61850 becomes more widely accepted in the electrical engineering community, it is important that the testing tools keep pace with this development. IEC 61850 presents new challenges to real time simulation and closed-loop testing of protective relays. Electrical interfaces used for binary signaling and voltage/current amplifiers must be replaced by an Ethernet connection and an IEC 6185...

متن کامل

Performance Evaluation of Protection Functions for Iec 61850-9-2 Process Bus Using Real-time Hardware-in-the-loop Simulation Approach

With the evolution of Process Bus (IEC 61850-9-2), there is a need to assess the performance of protection schemes using process bus against those where traditional copper wires are implemented. Differential protection is the fundamental and most commonly used protection for transformers, motors and generators. In this paper a power system is modelled in SimPowerSystems and is executed in real-...

متن کامل

Impact of IEC 61850-9-2 Standard-Based Process Bus on the Operating Performance of Protection IEDS: Comparative Study

IEC 61850-9-2 is an international substation automation standard that proposes a Process Bus communication network between process level equipment and bay level Intelligent Electronic Devices (IEDs) used for power systems protection and control. This paper considers the drive towards the use of IEC 61850-9-2 Process Bus in substations. The impact of the IEC 61850-9-2 standard on the operating p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of cyber security and mobility

سال: 2021

ISSN: ['2245-1439', '2245-4578']

DOI: https://doi.org/10.13052/jcsm2245-1439.1021