Recent Greek Provisions For Rc Structures with Urm Infills
نویسندگان
چکیده
منابع مشابه
Seismic Behaviour and Design of Mixed RC-URM Wall Structures
............................................................................................................................ v Riassunto ......................................................................................................................... vii Résumé ............................................................................................................................. i...
متن کاملDevelopment of a displacement-based design approach for modern mixed RC-URM wall structures
The recent re-assessment of the seismic hazard in Europe led for many regions of low to moderate seismicity to an increase in the seismic demand. As a consequence, several modern unreinforced masonry (URM) buildings, constructed with reinforced concrete (RC) slabs that provide an efficient rigid diaphragm action, no longer satisfy the seismic design check and have been retrofitted by adding or ...
متن کاملInfluence of Masonry Infills Walls on the Seismic Behaviour of Multi-storey Waffle Slabs Rc Buildings
In this work, we analyze the influence of masonry infill walls on the seismic performance of waffle slabs reinforced concrete (RC) framed structures. We analyze buildings of three, five and eight storeys, which are representative for a big number of housings in Barcelona, Spain. Capacity spectra have been obtained by performing pushover analyses and we have used a simplified procedure to obtain...
متن کاملEvaluation of the SEAOC/UBC97 Provisions for the Tall Base-Isolated Structures
The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...
متن کاملEvaluation of the SEAOC/UBC97 Provisions for the Tall Base-Isolated Structures
The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Open Construction and Building Technology Journal
سال: 2012
ISSN: 1874-8368
DOI: 10.2174/1874836801206010092