Recording characteristics on pulse train write current waveform.
نویسندگان
چکیده
منابع مشابه
Recording Characteristics, Microstructure, and Crystallization Kinetics of Ge/GeCu Recording Film Used for Write-Once Blu-Ray Disc
A Ge67Cu33 (16 nm) layer and a Ge (3 nm)/Ge67Cu33 (16 nm) bilayer were grown by sputtering at room temperature and used as the recording films for write-once blue laser media. In comparison to the crystallization temperature of Ge in a GeCu film (380.7 °C-405.1 °C), the crystallization temperature of Ge in a Ge/GeCu bilayer could be further decreased to 333.7 °C-382.8 °C. The activation energie...
متن کاملDesign of Monophasic Spike-Exponential Waveform for Functional Electrical Stimulator Based on Pulse Width Modulation
The Functional Electrical Stimulator design using monophasic spike-exponential waveform was proposed and described in this study. The monophasic square waveform has benefit in generating an action potential, but it could cause side effects such as toxic caused by the electrode polarization. The square waveform signal which the frequency and pulse width could be modulated was manipulated to be t...
متن کاملOn the estimation of interleaved pulse train phases
Some signals are transmitted as periodic pulse trains where information is in the timing of the arrival of the pulses. A number of pulse trains arriving over the same time interval are said to be interleaved. We propose an on-line method for estimating pulse train phases and fine-tuning pulse repetition frequency (PRF) estimates of a known number of interleaved pulse trains. The computational e...
متن کاملPulse waveform analysis and arterial wall properties.
Risk factors for cardiovascular disease mediate their effects by altering the structure, properties, and function of wall and endothelial components of arterial blood vessels.1 The ability to detect and monitor change in the physical properties of arteries, representative of the cumulative and integrated influence of hemodynamic, metabolic, and inflammatory stimuli in impairing arterial wall in...
متن کاملPulse train deinterleaving: algorithms and cost criteria
Consider the problem where pulse trains transmitted from a known number of sources are received on a single communications channel. These pulses are corrupted with noise. The deinterleaving problem is to determine which source contributed which pulse and the periods and phases of each source. This paper explores the performance of a number of deinterleaving algorithms. We propose an alternative...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Magnetics Society of Japan
سال: 1989
ISSN: 0285-0192
DOI: 10.3379/jmsjmag.13.129