Recovery of piecewise constant coefficients in optical diffusion tomography
نویسندگان
چکیده
منابع مشابه
Uniqueness for Diffusions with Piecewise Constant Coefficients
Let L be a second-order partial differential operator in R e. Let R e be the finite union of disjoint polyhedra. Suppose that the diffusion matrix is everywhere non singular and constant on each polyhedron, and that the drift coefficient is bounded and measurable. We show that the martingale problem associated with L is well-posed.
متن کاملRecovery of region boundaries of piecewise constant coefficients of an elliptic PDE from boundary data
In this study we consider the recovery of smooth region boundaries of piecewise constant coefficients of an elliptic PDE −∇ · a∇Φ + bΦ = f from data on the exterior boundary ∂Ω. The assumption is that the values of the coefficients (a, b) are known a priori but the information about the geometry of the smooth region boundaries where a and b are discontinous is missing. For the full characterisa...
متن کاملPiecewise Constant Aquifer Parameter Identification Recovery
For many inverse problems which arise in contributing to real-world decision-making, such as formulating policy objectives for freshwater fish health, only an indicative understanding of the global structure of the solution is all that is required for the associated decision-support. Examples include: (i) Situations where only some linear functional of the solution is required. As noted in vari...
متن کاملSimulating Diffusions with Piecewise Constant Coefficients Using a Kinetic Approximation
Using a kinetic approximation of a linear diffusion operator, we propose an algorithm that allows one to deal with the simulation of a multi-dimensional stochastic process in a media which is locally isotropic except on some surface where the diffusion coefficient presents some discontinuities. Basic numerical examples are given in dimensions one to three on PDEs or stochastic PDEs with or with...
متن کاملFluorescence optical diffusion tomography.
A nonlinear, Bayesian optimization scheme is presented for reconstructing fluorescent yield and lifetime, the absorption coefficient, and the diffusion coefficient in turbid media, such as biological tissue. The method utilizes measurements at both the excitation and the emission wavelengths to reconstruct all unknown parameters. The effectiveness of the reconstruction algorithm is demonstrated...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2000
ISSN: 1094-4087