Rectangular mode transformers in tapered single-mode fibres
نویسندگان
چکیده
منابع مشابه
Polarization mode coupling in long single-mode fibres
In this paper we look at the polarization state evolution of light propagating in long, birefringent, singlemode fibres in the presence of mode coupling. We show first that there always exist two orthogonal linear input polarizations which lead to linear output polarization for monochromatic light. The applicability of the coupled power equations is discussed and it is shown that they cannot be...
متن کاملBackscattering Measurement of Bending - Induced Birefringence in Single Mode Fibres
core were investigated. It was shown from the measurement that the beat length was about L = 23 mm (birefringence B = 5 x 10") and the state of linear polarisation of the incident light beam was maintained up to 0-6 kg/cm of the concentrated force when the incident plane of polarisation was coincident with the major axis of the fibre. It was also shown that the degree and the plane of polarisat...
متن کاملMode Order Converter Using Tapered Multi-mode Interference Couplers
Tapered MMI devices are proposed. It is demonstrated that the proposed single-stage MMI device's output power efficiency can be 55% higher than a conventional adiabatic taper by partially capturing the 2nd order mode power. ©2010 Optical Society of America OCIS codes: (130.3120) Integrated optics devices; (130.2790) Guided waves
متن کاملMode profile imaging and loss measurement for uniform and tapered single-mode 3D waveguides in diffusive photopolymer.
We demonstrate single-mode uniform and parabolically tapered three-dimensional waveguides fabricated via direct-write lithography in diffusion-based photopolymers. Modulation of the writing power is shown to compensate Beer-Lambert absorption in the single-photon initiator and to provide precise control of modal tapers. A laminated sample preparation is introduced to enable full 3D characteriza...
متن کاملPhase Current Differential Protection for Transformers in Wye-delta Mode
For the current transformers (CTs) on the delta side measure the line current instead of the phase current, line current differential protection is adopted in transformers connected in wye-delta mode currently. However, the symmetry feature of inrush current in line current differential protection may invalidate the inrush current restrained criterion. A calculating method of current through de...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Electronics Letters
سال: 1989
ISSN: 0013-5194
DOI: 10.1049/el:19890947