Rectum Dose Analysis Employing a Multi-purpose Brachytherapy Phantom

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-Dose-Rate 192Ir Brachytherapy Dose Verification: A Phantom Study

BACKGROUND The high-dose-rate (HDR) brachytherapy might be an effective tool for palliation of dysphagia. Because of some concerns about adverse effects due to absorbed radiation dose, it is important to estimate absorbed dose in risky organs during this treatment. OBJECTIVES This study aimed to measure the absorbed dose in the parotid, thyroid, and submandibular gland, eye, trachea, spinal c...

متن کامل

Monte Carlo calculation of shielded colpostat effect on rectum received dose in high dose rate brachytherapy with Cobalt-60 sources

Background: In the current study the effect of shielded colpostat on rectum received dose was calculated in cervical brachytherapy using Monte Carlo (MC) method. Materials and Methods: Two 60Co sources of GZP6 brachytherapy unit used for intracavitary treatments were simulated using MCNPX Monte Carlo code. Also the two types of colpostats including shielded and unshielded were simulated inside ...

متن کامل

A Multi-Purpose Dialogue Management System employing Visual Anthropomorphous Agent

We have been constructing a visual anthro-pomorphous agent system called Visual Software Agent(VSA). The VSA has a texture-mapped realistic human facial image and moves his/her face with facial expression in real-time. Also, it can recognize the speech dialogue of a user and can respond in synthesized voice sentence with synchronizing his/her mouth movement. This style of multi-modal dialogue s...

متن کامل

A novel phantom design for brachytherapy quality assurance

Background: One major challenge in brachytherapy is to verify the accuracy of dose distributions calculated by the treatment planning system. In this project, a new phantom design has been introduced for quality assurance of dose distributions in gynocological (GYN) brachytherapy implants using EBT GafChromic film. Materials and Methods: This phantom has been designed and fabricated from 90 sla...

متن کامل

The Effect of Breast Phantom Material on the Dose Distribution in AccuBoost Brachytherapy

Introduction: Long-term teletherapy program is not suitable for old and working patients and those living in areas where little access to primary health care is available. Accelerated partial breast irradiation (APBI) using high dose rate (HDR) brachytherapy is an appropriate alternative for these patients due to its limited number of fractions. The AccuBoost is a system for delivering APBI. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Japanese Journal of Clinical Oncology

سال: 2007

ISSN: 1465-3621,0368-2811

DOI: 10.1093/jjco/hym032