Reduced Reference Frame Transformation Assessment in Unbalanced Three-Phase Four-Wire Systems
نویسندگان
چکیده
Three-phase four-wire systems require a reference frame similar to that used in 3-phase 3-wire system configurations allow them be easily analysed, modelled and controlled. A new called Reduced Reference Frame (RRF) was presented by the authors previous work satisfy these objectives. This is based on locus of voltage space vector which perform transformation applied 4-wire systems. paper uses proposed RRF demonstrate benefits this under different conditions load or imbalance. To end, types imbalances considered are studied comparing results classical αβγ axes, so-called mno -transform specifically developed for coordinates. In addition, theoretical identification some done simulation fundamentals RRF.
منابع مشابه
Three-Phase, Four-Wire UPQC Topology with Reduced Switching Losses
The paper introduces the modified UPQC topology with reduced switching losses. UPQC is a versatile custom power device which consists of two inverters connected back to back and deals with both load current and supply voltage imperfections. It can simultaneously perform as shunt and series active power filters. The series part of the UPQC acts as Dynamic Voltage Restorer (DVR). It is used to ma...
متن کاملPi, Fuzzy Logic Controlled Shunt Active Power Filter for Three-phase Four-wire Systems with Balanced, Unbalanced and Variable Loads
This paper presents a fuzzy logic, PI controlled shunt active power filter used to compensate for harmonic distortion in three-phase four-wire systems. The shunt active filter employs a simple method for the calculation of the reference compensation current based on Fast Fourier Transform. The presented Shunt Active Power filter is able to operate in balanced, unbalanced and Variable load condi...
متن کاملAdaptive non-linear control of three-phase four-wire Shunt active power filters for unbalanced and non- linear loads
The problem of controlling three-phase, four-leg shunt active power filters (SAPF) is addressed in presence of nonlinear and/or unbalanced loads. A new control model for four-leg SAPF, taking into account for the electrical grid line impedance, is developed. The control objective is threefold: (i) compensating for the current harmonics and the reactive power absorbed by the nonlinear load; (ii)...
متن کاملA Three Phase Four Wire Shunt Active Power Filter Control Algorithm under Unbalanced and Distorted Supply Voltage
In this paper a control algorithm is validated with simulation studies in MAT environment and experimental studies are performed in to validate the proposed control algorithm. The projected algorithm to compensate the nonlinear and loads in three phase four wire distribution system using shunt active power filter. In this algorithm a positive sequence extraction of the supply voltage and the th...
متن کاملA Hybrid Control Method for Stable Operation of Active Power Filters in Three-Phase Four-Wire Networks
The main goal of this study is the use of Lyapunov’s stability theory to a three-phase four-wire shunt active power filter (SAPF), since this method has been applied effectively to other areas of converter. The dynamic model of the SAPF is first established, after that, a combination of fuzzy tracking control and Lyapunov function is suggested in order to impose a desired transient waveform on ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Access
سال: 2023
ISSN: ['2169-3536']
DOI: https://doi.org/10.1109/access.2023.3254299