Experimental Investigation on the Influence of Refrigerant Charge on the Performance of Trans-critical CO2 Water-Water Heat Pump
For the environmentally aware, natural refrigerant such as CO2 is recommended and pursued by researchers for refrigerators. In this paper, a transcritical CO2 heat pump system was set up to investigate the influence of refrigerant charge on the performance of a small-sized heat pump water heater. The transcritical CO2 heat pump system was composed of a rotary compressor, a tube-in-tube evaporat...
متن کاملInfluence of Refrigerant Charge Amount and EEV Opening on the Performance of a Transcritical CO2 Heat Pump Water Heater
Besides compressor rotary speed and parameters of water flowing through gas cooler and evaporator, refrigerant charge amount and electronic expansion valve (EEV) opening are two important parameters that have significant effects on the performance of a transcritical CO2 heat pump system. In this study, the effects of refrigerant charge amount on the performance of a transcritical CO2 heat pump ...
متن کاملFault diagnosis of refrigerant charge based on PCA and decision tree for variable refrigerant flow systems
Variable refrigerant flow (VRF) systems are easily subjected to performance degradation due to refrigerant leakage, mechanical failure or improper maintenance after years of operation. Ideal VRF systems should equip with fault detection and diagnosis (FDD) program to sustain its normal operation. This paper presents the fault diagnosis method for refrigerant charge faults of variable refrigeran...
متن کاملExperiences with the Refrigerant R134a as a "Drop-In" Replacement in a Large Water-Water-Heat Pump
A considerable amount of large scale heat pumps working mainly with Rl2 but also partially with Rll4 has been installed in Germany in the past. -As considerable investments have been made, a conversion from Rl2 to Rl34a seems to be an important task. Due to this reason a research project has been started at the University of Hannover to evaluate the possibility of such a conversion. To achieve ...
متن کاملExperimental Investigation on the Two-stage Compression Heat Pump Water Heater System with Refrigerant Injection
Nowadays heat pump water heater becomes a very hot topic in hot water industry. However it still has many problems such as higher condensing temperature, large-scale operation conditions and lower COP in cold regions. Based on these problems, the paper presents a prototype assembled with a two-stage rotary compressor which can be used in cold regions. The working principle and the basic feature...