Regadenoson Induces Comparable Left Ventricular Perfusion Defects as Adenosine
نویسندگان
چکیده
منابع مشابه
In an era of multimodality cardiac imaging, echocardiography remains the gold standard for the evaluation of valvular and periprosthetic masses.
et al. Adenosine versus regadenosoncomparative evaluation inmyocardial perfusion imaging: results of the ADVANCE phase 3 multicenter international trial. J Nucl Cardiol 2007;14:645–58. 17. Mahmarian JJ, Cerqueira MD, Iskandrian AE, Bateman TM, Thomas GS, Hendel RC et al. Regadenoson induces comparable left ventricular perfusion defects as adenosine: a quantitative analysis fromthe ADVANCE MPI 2...
متن کاملDipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings
Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...
متن کاملDiastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography
Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...
متن کاملNormal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT
Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...
متن کاملCardiovascular effects and tolerance of adenosine versus regadenoson during cardiac MRI perfusion testing
Background Patients referred to cardiac MRI (CMR) for suspicion of obstructive coronary artery disease typically undergo vasodilator stress testing using either adenosine or regadenoson. Both of these agents are effective and have been evaluated for stress testing in both the CMR and nuclear medicine setting but the cardiovascular physiologic effects of each of these agents have not been well s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JACC: Cardiovascular Imaging
سال: 2009
ISSN: 1936-878X
DOI: 10.1016/j.jcmg.2009.04.011