A Solid State Current Limiter

Abstract Utility engineers faced with the challenges of integrating new generation into existing power systems, clearing faults more quickly or finding an alternative to SF6 breakers will soon have a new product to meet all of their needs: a solid state current limiting circuit breaker. Electric utilities have long wished for a practical, reasonably priced, solid state circuit breaker which cou...

متن کامل

Solid State Electronic Fault Current Limiter to Limit the Fault Current in Power System

Increase in power generation capacity of electric power systems has lead to increase in the fault current level which can exceed the maximum designed short-circuit ratings of the switchgear. All the equipment therefore must have a short-circuit rating capable to withstand this level. Short-circuit currents contain extremely high energy and can damage electrical equipment. Typically, the circuit...

متن کامل

Fast Transient Fault-Current Detection Based on PQR Transformation Technique for a Solid-State Fault Current Limiter

Abstract: This paper describes analysis, modeling and simulation of electrical transient fault-current detection in power systems. The proposed modeling is based on simple numerical integration only, which is able to efficiently handle some sophisticated calculation. The proposed fault detector methods are sliding root mean square (SRMS) and PQR transformation technique. In this paper, an abnor...

متن کامل

Fault Current Limiter for a Distributed Power System

The up-gradation of an Electrical power generation network results in higher levels of short circuit fault current. Thereby, the existing protection equipment like circuit breakers, isolators and fuses become under capacity and not capable of withstanding higher short circuit currents. Thus the system is highly vulnerable to the adverse effects of short circuits. Replacing the whole protection ...

متن کامل

Reliability Analysis of Redundant Repairable System with Degraded Failure

This investigation deals with the transient analysis of the machine repair system consisting of M-operating units operating under the care of single repairman. To improve the system reliability/availability, Y warm standby and S cold standby units are provided to replace the failed units. In case when all spares are being used, the failure of units occurs in degraded fashion. In such situation ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Electronics

سال: 2017

ISSN: 0020-7217,1362-3060

DOI: 10.1080/00207217.2017.1378380