Removal of 17β-estradiol from secondary wastewater treatment plant effluent using Fe3+-Saturated montmorillonite

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrochemical disinfection of secondary wastewater treatment plant (WWTP) effluent.

In this work the electrochemical disinfection of the effluent of a secondary wastewater treatment plant is investigated. In the experimental work, performed on-site with real effluents of the WWTP located in Vuelta Ostrera (Cantabria, Spain), boron-doped diamond (BDD) electrodes were employed. The initial concentration of E. coli in the effluent of the WWTP varied in the range 1.3 x 10⁴-5.2 x 1...

متن کامل

Post-treatment of secondary wastewater treatment plant effluent using a two-stage fluidized bed bioreactor system

The aim of this study was to investigate the performance of a two-stage fluidized bed reactor (FBR) system for the post-treatment of secondary wastewater treatment plant effluents (Shahrak Gharb, Tehran, Iran). The proposed treatment scheme was evaluated using pilot-scale reactors (106-L of capacity) filled with PVC as the fluidized bed (first stage) and gravel for the filtration purpose (secon...

متن کامل

Pharmaceuticals in Wastewater Treatment Plant Effluent Waters

Pharmaceuticals are being used at an increasing rate, and end up in wastewater through excretion and disposal. They also end up in the effluent water of wastewater treatment plants because they are not specifically designed for pharmaceutical removal. Several studies suggest diverse negative effects on aquatic life that are exposed to these trace amounts of pharmaceuticals in their habitats. Th...

متن کامل

Nutrient Elimination from Effluent of Municipal Wastewater Treatment Plant Applying Horizontal Roughing Filter

High levels of turbidity and suspended solids are the major disadvantages of aerated lagoons. Aerated lagoon effluent filtration was investigated by Horizontal Roughing Filter (HRF). Removal efficiencies were determined by examining total phosphorus (TP) and total Kjeldahl Nitrogen (TKN) from HRF influent and effluent, simultaneously. HRF pilot system located on effluent pump station of Qom was...

متن کامل

Fate of sulfamethoxazole, 4-nonylphenol, and 17beta-estradiol in groundwater contaminated by wastewater treatment plant effluent.

Organic wastewater contaminants (OWCs) were measured in samples collected from monitoring wells located along a 4.5-km transect of a plume of groundwater contaminated by 60 years of continuous rapid infiltration disposal of wastewater treatment plant effluent. Fifteen percent of the 212 OWCs analyzed were detected, including the antibiotic sulfamethoxazole (SX), the nonionic surfactant degradat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Chemosphere

سال: 2019

ISSN: 0045-6535

DOI: 10.1016/j.chemosphere.2019.02.150