Removing air bubbles from a 1-ml syringe

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Blood gas analysis: effect of air bubbles in syringe and delay in estimation.

Two common sources of error in blood pH and blood gas analysis were studied. The effect of delay in estimation was studied in 10 volunteers and 40 patients. Syringes were stored at 0 degree C, (crushed ice), 4 degrees C (refrigerator) and 22 degrees C (room temperature). The pressure of oxygen (PO2) fell significantly by 20 minutes at 4 degrees C and 22 degrees C but did not change significantl...

متن کامل

A transient-flow syringe air permeameter

In response to the need to better describe spatial variations in permeability, we designed and built a new portable field air permeameter for use on rocks in outcrop and core. In this instrument, a chamber containing a small volume of air in contact with the rock is suddenly increased in volume creating a vacuum, causing air to flow from the rock into the chamber. The instantaneous chamber volu...

متن کامل

Efficacy of air/water syringe tip sterilization.

BACKGROUND Dental procedures involve contact between instruments and the patient's tissues, blood or saliva. This study evaluated the efficacy of the standardized sterilization of non-disposable air/water syringe tips and corrosion and contaminant build-up in these tips. METHODS The bacterial contamination of single-use and multiple-use non-disposable air/water syringe tips after routine use ...

متن کامل

Air bubbles under vertical vibrations.

This paper reports on an experimental study of the splitting instability of an air bubble a few centimetres in diameter placed in a sealed cylindrical cell filled with liquid and submitted to vertical oscillations. The response of the bubble to the oscillations is observed with a high-speed video camera. It is found that the bubble dynamics is closely associated with the acceleration of the cel...

متن کامل

The effects of air bubbles

We report on experiments on the effects of air bubbles on ultrasound velocity measurements in fluids. We used an acoustic Doppler velocimeter system for measuring the three velocity components in a single point and an acoustic Doppler velocimetry profiler system for measuring axial velocity in several points along the beam. The results suggest that both systems essentially measure the velocity ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Anaesthesia

سال: 2018

ISSN: 0003-2409

DOI: 10.1111/anae.14229