REMOVING GOLD COATING FROM SEM SAMPLES
نویسندگان
چکیده
منابع مشابه
SEM Study on Old-styled Thai Gold Mosaic Glass Samples
Gold Mosaic glass has been used to decorate items and places since ancient time. The glass structure is divided into three layers: cover glass, gold layer and glass substrate. In this study, the composition of old-styled Thai gold mosaic glass samples was analyzed using SEM/EDX and Raman spectroscopy. It was found that the glass composition was sodiumsilicate based glass. Raman spectroscopy als...
متن کاملCryo-SEM studies of latex/ceramic nanoparticle coating microstructure development.
Cryogenic scanning electron microscopy (cryo-SEM) was used to investigate microstructure development of composite coatings prepared from dispersions of antimony-doped tin oxide (ATO) nanoparticles (approximately 30 nm) or indium tin oxide (ITO) nanoparticles (approximately 40 nm) and latex particles (polydisperse, D(v): approximately 300 nm). Cryo-SEM images of ATO/latex dispersions as-frozen s...
متن کاملDouble layer coating for high resolution low temperature SEM
Specimen damage caused by mass loss due to electron beam irradiation is a major limitation in Low Temperature Scanning Electron Microscopy of bulk specimens. At high primary magnifications (e.g. 100 000 x) a hydrated sample is usually severely damaged after one slow scan (about 3000 enm-2). The consequences of this beam damage are remarkably reduced by coating the frozen-hydrated sample with a ...
متن کاملAvoiding Boosting Overfitting by Removing Confusing Samples
Boosting methods are known to exhibit noticeable overfitting on some datasets, while being immune to overfitting on other ones. In this paper we show that standard boosting algorithms are not appropriate in case of overlapping classes. This inadequateness is likely to be the major source of boosting overfitting while working with real world data. To verify our conclusion we use the fact that an...
متن کاملD uble layer coating for high resolution low temperature SEM
Specimen damage caused by mass loss due to electron beam irradiation is a major limitation in Low Temperature Scanning Electron Microscopy of bulk specimens. At high primary magnifications (e.g. 100 000 x) a hydrated sample is usually severely damaged after one slow scan (about 3000 enm-2). The consequences of this beam damage are remarkably reduced by coating the frozen-hydrated sample with a ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Palaeontology
سال: 2007
ISSN: 0031-0239,1475-4983
DOI: 10.1111/j.1475-4983.2007.00718.x