Repeatability and Reproducibility of Fetal Cardiac Ventricular Volume Calculations Using Spatiotemporal Image Correlation and Virtual Organ Computer-Aided Analysis
نویسندگان
چکیده
منابع مشابه
Fetal cardiac function: M-mode and 4D spatiotemporal image correlation.
Fetal cardiac function has been shown to be a marker of disease severity in many conditions, including intrauterine growth restriction, congenital heart defects or disease (CHD), twin-to-twin transfusion syndrome, idiopathic hydrops, fetal arrhythmias, and others. It is often targeted for evaluation of patient management, for providing complete and accurate diagnoses in CHD, for patient counsel...
متن کاملReproducibility of transvaginal three-dimensional endometrial volume measurements with virtual organ computer-aided analysis (VOCAL) during ovarian stimulation.
OBJECTIVE To calculate inter- and intraobserver reliabilities for three-dimensional endometrial volume measurements during in vitro fertilization using virtual organ computer-aided analysis (VOCAL). PATIENTS AND METHODS Three-dimensional ultrasound measurements of the endometrium using VOCAL software were performed on the day of oocyte retrieval in each of 79 consecutive patients undergoing i...
متن کاملNew Insight from Using Spatiotemporal Image Correlation in Prenatal Screening of Fetal Conotruncal Defects
متن کامل
Efficacy of fetal thigh volumetry in predicting birth weight using the virtual organ computer-aided analysis (VOCAL) technique.
OBJECTIVES The present study was conducted to compare the accuracy of formulas used to calculate fetal thigh volume (FTV) using the virtual organ computer-aided analysis (VOCAL) technique with two-dimensional (2D) in formulas predicting birth weight. MATERIALS AND METHODS This was a prospective, cross-sectional study of 84 pregnant women with 72 hours of delivery evaluated at a university hos...
متن کاملThree-dimensional ultrasonographic bladder volume measurement: reliability of the Virtual Organ Computer-Aided Analysis technique using different rotation steps.
OBJECTIVE The purpose of this study was to investigate the reliability of Virtual Organ Computer-Aided Analysis (VOCAL; GE Healthcare, Kretztechnik, Zipf, Austria) using the 4 standard rotation steps to measure the bladder volume with 3-dimensional (3D) ultrasonography. METHODS Using the 4 standard rotation steps of VOCAL, 2 independent observers made 3D volume measurement data sets from the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Ultrasound in Medicine
سال: 2009
ISSN: 0278-4297
DOI: 10.7863/jum.2009.28.10.1301