Report for Maintenance Air Cooled Chiller Power Ciat 2800X
نویسندگان
چکیده
منابع مشابه
Application of Air - Cooled Chiller for Comfort and Energy Saving
In this study, a frequency converter was used to carry out variable frequency control to the compressor with constant frequency of a small 3RT central air-conditioning air-cooled chiller, but the indoor blower and cooled water pump were still kept by constant frequency operation. It is to explore the energy-saving effect of chiller compressor and the cooling fan after being carried out the vari...
متن کاملControl of Air-Cooled Chiller Condenser Fans using Clustering Neural Networks
This study investigates task -blind and task -specific training methods to determine appropriate radial basis function based neural network architectures. These neural nets identify system behavior of air-cooled chiller condensers by grouping dominant features (clustering) of measured chiller performance data. Task specific clustering proved superior but more computationally demanding than task...
متن کاملSolar-Enhanced Air-Cooled Heat Exchangers for Geothermal Power Plants
This paper focuses on the optimization of a Solar-Enhanced Natural-Draft Dry-Cooling Tower (SENDDCT), originally designed by the Queensland Geothermal Energy Centre of Excellence (QGECE), as the air-cooled condenser of a geothermal power plant. The conventional method of heat transfer augmentation through fin-assisted area extension is compared with a metal foam-wrapped tube bundle. Both lead t...
متن کاملOptimization of Water - Cooled Chiller – Cooling Tower Combinations
Water-cooled chiller systems have typically been designed around entering condenser water temperatures of 85°F with a Optimization of Water Cooled Chiller – Cooling Tower Combinations The warm water leaving the chilled water coils is pumped to the evaporator of the chiller, where the unwanted heat from the building is transferred by the latent heat of vaporization of the refrigerant. The compre...
متن کاملChip Temperature-Based Workload Allocation for Holistic Power Minimization in Air-Cooled Data Center
Minimizing the energy consumption is a dominant problem in data center design and operation. To cope with this issue, the common approach is to optimize the data center layout and the workload distribution among servers. Previous works have mainly adopted the temperature at the server inlet as the optimization constraint. However, the inlet temperature does not properly characterize the server’...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Oriental Journal of Physical Sciences
سال: 2020
ISSN: 2456-799X
DOI: 10.13005/ojps04.02.04