In this paper, a small signal model based on droop controller is established for the self-synchronous voltage source parallel system. The influence of coefficient system stability analysed, and constraint conditions are given. Based analysis inverter, multi-machines control scheme inverter formulated. test platform built to carry out simulation experimental verification distributed line impedance parameters. Simulation results show that proposed strategy can achieve good dynamic steady-state power sharing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fault-Tolerant Voltage Source Inverter for Permanent Magnet Synchronous Motor

A two level fault tolerant voltage sourse inverter(VSI) for permanent magnetic drives is designed and tested. Generally a two level inverter consists of three legs. In this case an extra (redundant ) leg is added that replaces the fault leg. Extra leg is added by using by back to back connected thyristor this inverter works on both open circuit and short circuit fault. The main advantage is pos...

متن کامل

Analysis of Model Predictive Current Control for Voltage Source Inverter

Abstract: Model predictive control has become a promising control technology in power converter, because of the good dynamic response and accurate current tracking capability. This study mainly analyzes and verifies the Model Predictive Current control (MPC) of a three-phase voltage sources converter. The MPC controller predicts the behavior of the converter for each possible voltage vector on ...

متن کامل

Control of Inverter-Interfaced Distributed Generation Units for Voltage and Current Harmonics Compensation in Grid-Connected Microgrids

In this paper, a new approach is proposed for voltage and current harmonics compensation in grid-connected microgrids (MGs). If sensitive loads are connected to the point of common coupling (PCC), compensation is carried out in order to reduce PCC voltage harmonics. In absence of sensitive loads at PCC, current harmonics compensation scenario is selected in order to avoid excessive injection of...

متن کامل

The Vector Control of Three-Phase Salient Pole Synchronous Machines Supplied by Pulse-Width- Modulated Voltage Source Inverters

In this paper, computer simulation of a three-phase synchronous motor drive is described. This drive/system is supplied with a new type of pulse-width modulated voltage source inverter (PWM VSI) whose amplitude of the first harmonic, compared to a conventional sinusoidal PWM VSI, is increased by about 17% and whose amplitude of higher harmonics is also reduced inversely proportional to their or...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: E3S web of conferences

سال: 2021

ISSN: ['2555-0403', '2267-1242']

DOI: https://doi.org/10.1051/e3sconf/202123101006