Resistance of three implant-abutment interfaces to fatigue testing
                    
                        
                            نویسندگان
                            
                            
                        
                        
                    
                    
                    چکیده
منابع مشابه
Resistance of three implant-abutment interfaces to fatigue testing
UNLABELLED The design and retentive properties of implant-abutment connectors affect the mechanical resistance of implants. A number of studies have been carried out to compare the efficacy of connecting mechanisms between abutment and fixture. OBJECTIVES The aims of this study were: 1) to compare 3 implant-abutment interfaces (external hexagon, internal hexagon and cone-in-cone) regarding th...
متن کاملManual maximum closing torque in three implant abutment systems
Background and Aims: Diferences whithin shape and size of hand wrenches in diferent systems could affect the torque applied. Therefore, evaluation of wrenches has been emphasized. The aim of the present study was to compare the torque values of the long and short torque wrenches in different implant systems including ITI, Implantium and Nobel Biocare. Materials and Methods: In this experimenta...
متن کاملMarginal accuracy of three implant-ceramic abutment configurations.
PURPOSE Microgaps at the implant-abutment interface allow for microbial colonization, which can lead to peri-implant tissue inflammation. This study sought to determine the marginal accuracy of three different implant-zirconium oxide (zirconia) abutment configurations and one implant?titanium abutment configuration. MATERIALS AND METHODS Three combinations of implants with custom-made zirconi...
متن کاملMechanical testing of implant-supported anterior crowns with different implant/abutment connections.
PURPOSE This study evaluated the reliability and failure modes of anterior implants with internal-hexagon (IH), external-hexagon (EH), or Morse taper (MT) implant-abutment interface designs. The postulated hypothesis was that the different implant-abutment connections would result in different reliability and failure modes when subjected to step-stress accelerated life testing (SSALT) in water....
متن کاملElectronic assessment of peri-implant mucosal esthetics around three implant-abutment configurations: a randomized clinical trial.
OBJECTIVES To objectively assess the influence that three different implant-abutment interface designs had on peri-implant mucosal esthetics at 1 year post-implant placement via the pink esthetic score (PES). Additionally, to demonstrate the novel employment of a tablet-based digital imaging format to reliably assess and score clinical images as part of a multicenter clinical trial according to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Applied Oral Science
سال: 2011
ISSN: 1678-7765,1678-7757
DOI: 10.1590/s1678-77572011005000018