Resolution Analysis in a Lens-Free On-Chip Digital Holographic Microscope
نویسندگان
چکیده
منابع مشابه
Dictionary-based phase retrieval for space-time super resolution using lens-free on-chip holographic video
We propose a dictionary-based phase retrieval approach for monitoring in vivo biological samples based on lens-free on-chip holographic video. Our results present a temporal increase of 9× with 4×4 sub-sampling. OCIS codes: 090.1995, 100.5070, 110.1758.
متن کاملLens-free optical tomographic microscope with a large imaging volume on a chip.
We present a lens-free optical tomographic microscope, which enables imaging a large volume of approximately 15 mm(3) on a chip, with a spatial resolution of < 1 μm × < 1 μm × < 3 μm in x, y and z dimensions, respectively. In this lens-free tomography modality, the sample is placed directly on a digital sensor array with, e.g., ≤ 4 mm distance to its active area. A partially coherent light sour...
متن کاملCompact in-line lensfree digital holographic microscope
Phase imaging provides intensity contrast to visualize transparent samples such as found in biology without any staining. Among them, digital holographic microscopy (DHM) is a well-known quantitative phase method. Lensfree implementations of DHMs offer the added advantage to provide large field of views (several mm2 compared to several hundred μm2) and more compact setups that traditional DHM w...
متن کاملMems Measurement by Digital Holographic Microscope
A universal digital holographic microscope to measure shape and displacement of microelement and MEMS (MicroElectroMechnacalSystems) is presented. This device is designed to exploit a measurement for MEMS with either a smooth or a rough surface. The method is based on digital laser interferometry and digital laser speckle interferometry (TV holography) incorporated with optoelectronic devices i...
متن کاملCo-design of an in-line holographic microscope with enhanced axial resolution: selective filtering digital holography.
Common-path digital in-line holography is considered as a valuable 3D diagnostic technique for a wide range of applications. This configuration is cost effective and relatively immune to variation in the experimental environment. Nevertheless, due to its common-path geometry, the signal-to-noise ratio of the acquired hologram is weak as most of the detector (i.e., CCD/CMOS sensor) dynamics are ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Computational Imaging
سال: 2020
ISSN: 2333-9403,2334-0118,2573-0436
DOI: 10.1109/tci.2020.2964247