Responsiveness and Minimal Clinically Important Difference of the Five Times Sit-to-Stand Test in Patients with Stroke

نویسندگان

چکیده

This study aimed to analyze the responsiveness of 5STS test among stroke patients and estimate MCIDs (minimal clinically important differences) for different severity levels community ambulation stages recovery. The comparator instruments (gait speed Functional Ambulatory Category (FAC)) were evaluated at baseline. These measures repeated 4 (Stage 1) 8 weeks 2), together with Global Rating Change (GROC). calculated two anchor-based methods using GROC as external criterion. Responsiveness change was estimated analyzing correlation changes in their capacity discriminate improvement. For test, while limited ambulators similar (around 3 s), those household decreased from 1.9 s 0.72 s. Spearman’s rho coefficients showed an acceptable between both FAC gait Our revealed that is responsive functional degree stage recovery influence MCID values 5STS.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Five times sit-to-stand test performance in Parkinson's disease.

OBJECTIVES To (1) determine intrarater and test-retest reliability of the Five times sit-to-stand test (FTSTS) in Parkinson's disease (PD), (2) characterize FTSTS performance in PD at different disease stages, (3) determine predictors of FTSTS performance in PD, and (4) determine the utility of the FTSTS for discriminating between fallers and nonfallers with PD, identifying an appropriate cutof...

متن کامل

Association of Seat Height and Arm Position on the Five Times Sit-to-Stand Test Times of Stroke Survivors

OBJECTIVES To investigate (1) the association of seat height and (2) the association of arm position on the five times sit-to-stand test (FTSTS) times of individuals with stroke. DESIGN A cross-sectional study. SETTING University-based rehabilitation centre. SUBJECTS Patients (n = 43) with chronic stroke. METHODS The times in completing the FTSTS with different seat height (85%, 100%, a...

متن کامل

Foot Placement and Arm Position Affect the Five Times Sit-to-Stand Test Time of Individuals with Chronic Stroke

OBJECTIVES To investigate the effect of two foot placements (normal or posterior placement) and three arm positions (hands on the thighs, arms crossed over chest, and augmented arm position with elbow extended) on the five times sit-to-stand (FTSTS) test times of individuals with chronic stroke. DESIGN Cross-sectional study. Setting. University-based rehabilitation clinic. PARTICIPANTS A co...

متن کامل

Responsiveness and minimal clinically important difference for pain and disability instruments in low back pain patients

BACKGROUND The choice of an evaluative instrument has been hampered by the lack of head-to-head comparisons of responsiveness and the minimal clinically important difference (MCID) in subpopulations of low back pain (LBP). The objective of this study was to concurrently compare responsiveness and MCID for commonly used pain scales and functional instruments in four subpopulations of LBP patient...

متن کامل

Falls classification using tri-axial accelerometers during the five-times-sit-to-stand test.

The five-times-sit-to-stand test (FTSS) is an established assessment of lower limb strength, balance dysfunction and falls risk. Clinically, the time taken to complete the task is recorded with longer times indicating increased falls risk. Quantifying the movement using tri-axial accelerometers may provide a more objective and potentially more accurate falls risk estimate. 39 older adults, 19 w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Environmental Research and Public Health

سال: 2021

ISSN: ['1661-7827', '1660-4601']