The paper presents a case study where the energy demand for a listed building constructed in 1900 is reduced. Many older buildings are listed and have restrictions that include the entire building or that include only its exterior. For the building presented, only its exterior facade is listed. The paper demonstrates measures for the improvement of the thermal insulation of the building with so...
متن کاملEnergy savings and economics of retrofitting single-family buildings
This s tudy a s se s se s the energy savings and cost-effect iveness of individual retrofi t op t ions and packages of measu res in s ingle-family buildings, ba sed on analysis of me te red energy consumpt ion and actual installation costs. We present results for 14 individual shell, heating system, and water heating measures, as well as 21 electric utility weatherization programs. The data on ...
متن کاملInvestigating Efficiency of Shotcrete for Retrofitting Masonry Buildings
One of a feasible and efficient method to retrofit structures is spraying shotcrete which is widely applied around the world. Shotcrete is concrete with fine aggregates which are sprayed through a hose and by air pressure coat at high velocity onto a surface. In the current research, three masonry schools from different regions of Iran are selected. The retrofitted wall surfaces have been prepa...
متن کاملRemarks on the green retrofitting of historic buildings in Italy
Latest European Union programs related to energy efficiency underline the need for retrofitting existing buildings, which are responsible for 40% of EU final energy consumption. Although new buildings can be constructed with high performance levels, the majority of the building stock, characterized by a low energy performance, still needs renovation. Thanks to its potential to deliver high ener...
متن کاملA Retrofitting Framework for Pre-Northridge Steel Moment-Frame Buildings
A case study of retrofitting a 20-story pre-Northridge steel moment-frame building is presented. Twelve retrofit 4 schemes are developed with varying degrees of intervention. Three retrofitting techniques are considered: up5 grading the brittle beam-to-column moment resisting connections, and implementing either conventional or 6 buckling-restrained brace elements within the existing moment-fra...