Retrospective motion correction for Fast Spin Echo based on conditional GAN with entropy loss

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast Spin Echo Imaging

In conventional spin echo (SE) imaging, the longitudinal magnetization (that is generated by the presence of the main magnetic field, B0) is tipped into the transverse plane using a radiofrequency (RF) pulse that tips the magnetization 90 degrees. Once in the transverse plane, the magnetization rotates, or precesses, around the axis of the main magnetic field. As the transverse magnetization pr...

متن کامل

Fast Spin- Echo

Imaging with T2-weighting is prescribed in nearly every diagnostic imaging protocol, owing to the fact that in many pathologic states, diseased tissue may be distinguished from normal tissue through apparent differences in T2. Conventional T2-weighted imaging carries with it a heavy time cost, however, as a relatively long time must be allowed between acquisitions in order to allow T1 recovery ...

متن کامل

Interactive fast spin-echo imaging.

It is shown that a spin-echo sequence may be used to acquire T(2)-weighted, high-resolution, high-SNR sections at quasi-real-time frame rates for interactive, diagnostic imaging. A single-shot fast spin-echo sequence was designed which employs driven equilibrium to realign transverse magnetization remaining at the final spin echo. Driven equilibrium is shown to improve T(2) contrast at a given ...

متن کامل

Three-dimensional fast-recovery fast spin-echo MRCP: comparison with two-dimensional single-shot fast spin-echo techniques.

PURPOSE To retrospectively evaluate the technical quality of and the visibility of the biliary tree and pancreatic duct on magnetic resonance (MR) cholangiopancreatographic (MRCP) images obtained with a single-breath-hold three-dimensional (3D) fast-recovery fast spin-echo (FRFSE) sequence in comparison with conventional two-dimensional (2D) single-shot fast spin-echo (SSFSE) thin-section and t...

متن کامل

Characteristics of Spondylotic Myelopathy on 3D Driven-Equilibrium Fast Spin Echo and 2D Fast Spin Echo Magnetic Resonance Imaging: A Retrospective Cross-Sectional Study

In patients with spinal stenosis, magnetic resonance imaging of the cervical spine can be improved by using 3D driven-equilibrium fast spin echo sequences to provide a high-resolution assessment of osseous and ligamentous structures. However, it is not yet clear whether 3D driven-equilibrium fast spin echo sequences adequately evaluate the spinal cord itself. As a result, they are generally sup...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Physics: Conference Series

سال: 2021

ISSN: 1742-6588,1742-6596

DOI: 10.1088/1742-6596/1848/1/012118