Is Distal Femur Locking Plate a Superior Implant in Distal Femur Fracture?

In spite of advances in techniques and improvements in surgical implants, confusion still prevails regarding use of specific implants in distal femur fracture. Fractures in the distal femur have posed considerable therapeutic challenges throughout the history of fracture treatment. Most of these surgical failures were due to inadequate fixation of the fracture fragments. The Aim of the study is...

متن کامل

Reverse distal femoral locking compression plate a salvage option in nonunion of proximal femoral fractures

BACKGROUND When primary fixation of proximal femoral fractures with implants fails, revision osteosynthesis may be challenging. Tracts of previous implants and remaining insufficient bone stock in the proximal femur pose unique problems for the treatment. Intramedullary implants like proximal femoral nail (PFN) or surface implants like Dynamic Condylar Screw (DCS) are few of the described impla...

متن کامل

Reversed anatomic distal femur locking plate for periprosthetic hip fracture fixation.

The incidence of femoral fracture on hip prosthesis is increasing. Plate fixation is the method of choice when the prosthesis is stable. In fracture with proximal extension, the quality of the bone fixation is critical and, despite the development of anatomic plates, may be endangered when there are too few proximal screws. To resolve this issue, we recommend using a reversed LCP™ anatomic dist...

متن کامل

Outcome of pertrochantric fracture of the femur treated with proximal femoral locking compression plate.

Pertrochantric femoral fractures are one of the most common fracture in old patients with variety of complications. However fixing Pertrochantric femoral fractures properly is clinically challenging. We report the outcome of pertrochantric femoral fractures treated with Proximal Femoral Locking Compression Plate (PFLCP) using Minimal Invasive Percutaneous Plate Osteosynthesis (MIPPO) techniques...

متن کامل

Failure of Distal Femoral Locking Plate: Case Report

The Less Invasive Stabilization System (LISS) and titanium distal femoral locking compression plate (DF-LCP) was designed by the AO Group to combine the advantages of both interlocked intra-medullary nailing and biological plating techniques in one system. The stiffness of the construct is similar to a 95° condylar plate, dynamic condylar screw, or condylar buttress plate. We report a case of t...