Review on Failure Modes of Masonry Infill Frames
نویسندگان
چکیده
منابع مشابه
Analysis of Masonry Infill Panels Retrofitted with FRP Sheets in R/C Frames
Masonry infill walls are often used as non-structural elements. According to the past structural failure, ignorance of interaction between infill walls and enclosed frame may lead to the different seismic response for non-ductile building frames. The main contribution of this paper is to analytically investigate the behavior of reinforced concrete with masonry infill panels as participating str...
متن کاملModeling of FRP-Strengthened Infill Masonry Structures
This paper presents an analytical approach to describe the behavior and mode of failure of infill masonry structures strengthened with fiber-reinforced polymer (FRP) materials. The approach is used to simulate the response of strengthened infill masonry walls under the effect of out-of-plane uniformly distributed pressure simulating wind pressure. The approach includes a finite element analysis...
متن کاملRetrofit of Un-Reinforced Infill Masonry Walls with FRP
This paper describes an experimental program that deals with retrofitting of infill un-reinforced masonry walls (URM) with Fiber Reinforced Polymer (FRP). The primary objective of this research is to develop a retrofit strategy that while economical will minimize the influence of the retrofit on the overall performance of structural frames in predominant seismic regions. Allowing some damage to...
متن کاملFuzzy Fragility Analysis of Structures with Masonry Infill Walls
In this work fragility analysis of reinforced concrete and steel structures withinfill walls is performed.For this purpose a fuzzy-based fragility assessment framework for evaluating 3D framed structures is proposed taking into account various sources of uncertainty. In particular, randomness on the material properties and on the seismic demand is considered. The proposed framework requires the...
متن کاملNew Frp and Adhesive Materials for Strengthening Infill Masonry Structures
ABSTRACT: This paper explores the behavior of infill masonry structures strengthened with a new type of Fiber Reinforced Polymer (FRP) strengthening system with high fracture strain know as PET (Polyethylene Teraphthalate) and a new near-surface mounted (NSM) Carbon fiber strengthening system using a cementitious material as the adhesive as compared to a Glass Fiber (GFRP) strengthening system ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Engineering and Techniques
سال: 2020
ISSN: 2395-1303
DOI: 10.29126/23951303/ijet-v6i3p10