Revisiting molecular weight distribution of polystyrenes using adsorption high-performance thin-layer chromatography

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Revisiting molecular weight distribution of polystyrenes using adsorption high-performance thin-layer chromatography

A repeatable separation of polystyrenes according to MW, from 1920 to 520000 u.m.a, has been obtained under adsorption conditions using a method that comprises the use of Lichrospher HPTLC plates, and a controlled, isocratic elution with a 78:22 (v/v) mixture of cyclohexane (Cy)-tetrahydrofuran (THF). Likewise, UV-densitometric quantification of polystyrenes in mixtures can be achieved, by an i...

متن کامل

Quantitative Estimation of Efavirenz by High Performance Thin Layer Chromatography

A simple, accurate, and precise HPTLC method has been developed and validated for the estimation of efavirenz from bulk drug and capsule formulations. The separation was achieved on TLC plates using an appropriate solvent system. The spots so developed were densometrically scanned at 247 nm. The linearity of the method was found to be within the concentration range of 1-40 μg/ml. The validation...

متن کامل

Simultaneous Analysis and Quantification of Markers of Manjisthadi Churna Using High Performance Thin Layer Chromatography

Manjisthadi churna has been traditionally used in the Ayurvedic system of medicine and by traditional medical practices of India to treat hyperlipidemia. A rapid, simple and accurate method with high performance thin layer chromatography has been developed to standardised Manjisthadi churna using rubiadin, sennoside and ellagic acid as markers. Methanol extract of Manjisthadi churna were used f...

متن کامل

Determination of Ochratoxin A in Wine by High-Performance Thin-Layer Chromatography using Charged Coupled Device

Um método foi desenvolvido e validado para a determinação de ocratoxina A (OTA) em vinho. Foi utilizado um sistema contendo um detector de carga acoplada (CCD) para adquirir as imagens fluorescentes da micotoxina obtidas a partir das placas de cromatografia em camada delgada de alta eficiência (HPTLC) sob luz ultravioleta. O método desenvolvido mostrou recuperação média de 90,4%. O limite de qu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Planar Chromatography – Modern TLC

سال: 2013

ISSN: 0933-4173,1789-0993

DOI: 10.1556/jpc.26.2013.1.1