Ripple Reduction Using Seven-Level Shunt Active Power Filter for High-Power Drives
نویسندگان
چکیده
منابع مشابه
Power System Harmonic Reduction Using Shunt Active Filter
This paper shows the method of improving the power quality using shunt active power filter. The proposed topic comprises of PI controller, filter hysteresis current control loop, dc link capacitor. The switching signal generation for filter is from hysteresis current controller techniques. With the all these element shunt active power filter reduce the total harmonic distortion. This paper repr...
متن کاملHigh Performance Seven Level Active Shunt Filter for Harmonic Mitigation
This paper deals with the simulation of a shunt active filter using seven level cascaded H-bridge multilevel inverter. The proposed active filter topology can also produce seven voltage levels, which significantly reduces the switching current ripple and the size of passive components. The seven level active shunt filter provides compensation of load power factor and current harmonics. For comp...
متن کاملPower System Harmonic Compensation Using Shunt Active Power Filter
This paper shows the method of improving the power quality using shunt active power filter. The proposedtopic comprises of PI controller, filter hysteresis current control loop, dc link capacitor. The switching signal generation for filter is fromhysteresis current controller techniques. With the all these element shunt active power filter reduce the total harmonic distortion. Thispaper represe...
متن کاملShunt Active Filter for Power Quality Improvement
This paper describes the development of a low cost shunt active power filter with digital control, which allows dynamic power factor correction and both harmonics and zero-sequence current compensation. The active filter controller is based on the instantaneous power theory (p-q theory) and was implemented using a standard 16 bits microcontroller. The p-q theory is introduced followed by the pr...
متن کاملThree Level Inverter Based Shunt Active Power Filter Using Multi-Level Hysteresis Band Current Controller
In this paper, a three-level inverter based Shunt Active Power Filter (SAPF) using Multi-Level Hysteresis Current Controller (MLHCC) is presented for solution of power quality problems in distribution system. A simulation model of SAPF is prepared in Matlab/Simulink environment. MLHCC is used for control of SAPF currents. In simulation study, it is considered that SAPF executes two tasks coveri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering