Robertshaw endobronchial tubes.
نویسندگان
چکیده
منابع مشابه
Comparison of the resistances of double-lumen endobronchial tubes.
The resistance of commonly-used double-lumen endobronchial tubes were measured and a detailed comparison made. Robertshaw tubes were generally found to have a lower resistance than either the Carlens or the White tubes of equivalent size, but this was not so in every case. The White tubes had a disproportionately high resistance associated with the upper lobe orifice when compared with the resi...
متن کاملLeft mainstem bronchial rupture during one-lung ventilation with Robertshaw double lumen endobronchial tube -A case report-
Lung separation using a double-lumen endobronchial tube is necessary for video assisted thoracoscopy (VATs). Bronchial rupture after intubation with a double-lumen endobronchial tube has been rarely reported. We report a case of a 70-year-old man who had solitary pulmonary nodule in his right upper lobe. He was intubated with a left-sided Robertshaw double-lumen endobronchial tube. He underwent...
متن کاملGiant Endobronchial Inflammatory Polyp
Inflammatory endobronchial polyp is a rare disease mostly encountered in asthmatic patients. Chronic airway and foreign material irritation or thermal injury may result in the formation of granulated tissues and become polypoid mass. Herein, we describe a 52-year-old man with severe respiratory distress and infection with 35 years history of smoking. He had an obstructive pattern in his pulmona...
متن کاملPlacement of double-lumen endobronchial tubes. Correlation between clinical impressions and bronchoscopic findings.
Double-lumen endobronchial tubes were placed "blindly" in 23 patients undergoing thoracotomy. Clinical criteria suggested satisfactory positioning in all cases; however, subsequent fibreoptic bronchoscopy revealed malposition in 48%. Bronchoscopic findings included the inability to view the bronchial cuff, narrowing of the bronchial lumen of the tube at the level of the cuff and herniation of t...
متن کاملModified and newly designed right-sided double-lumen endobronchial tubes are complementary.
To the Editor:—We read with great interest the case report on the application of a newly designed right-sided, double-lumen endobronchial tube (R-DLT) in patients with a very short right mainstem bronchus. However, in citing our work on the improvement of the endobronchial positioning of the R-DLT, Hagihira et al. stated that we modified the design of the bronchial cuff and that these changes s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Anaesthesia
سال: 1973
ISSN: 0003-2409,1365-2044
DOI: 10.1111/j.1365-2044.1973.tb00501.x