Robot Calibration. Industrial Robot Calibration Method and Its Application for Production Line.
نویسندگان
چکیده
منابع مشابه
Estimation and Calibration of Robot Link Parameters with Intelligent Techniques
Abstract: Using robot manipulators for high accuracy applications require precise value of the kinematics parameters. Since measurement of kinematics parameters are usually associated with errors and accurate measurement of them is an expensive task, automatic calibration of robot link parameters makes the task of kinematics parameters determination much easier. In this paper a simple and easy ...
متن کاملA Method for Inverse Robot Calibration
A method is described for the inverse calibration of a manipulator or robot. Inverse calibration is defined to be finding the joint angles necessary to drive a robot to a desired endpoint location. The joint angles recommended by the robot controller's internal model will not, in general, drive the robot to the desired location because of inaccuracies in this model. Inverse calibration seeks to...
متن کاملA Rapid Coordinate Transformation Method Applied in Industrial Robot Calibration Based on Characteristic Line Coincidence
Coordinate transformation plays an indispensable role in industrial measurements, including photogrammetry, geodesy, laser 3-D measurement and robotics. The widely applied methods of coordinate transformation are generally based on solving the equations of point clouds. Despite the high accuracy, this might result in no solution due to the use of ill conditioned matrices. In this paper, a novel...
متن کاملOptimization of Measurement Configurations for Geometrical Calibration of Industrial Robot
The paper is devoted to the geometrical calibration of industrial robots employed in precise manufacturing. To identify geometric parameters, an advanced calibration technique is proposed that is based on the non-linear experiment design theory, which is adopted for this particular application. In contrast to previous works, the calibration experiment quality is evaluated using a concept of the...
متن کاملFixture-based industrial robot calibration for silicon wafer handling
1 This work was supported in part by Adept Technology, Inc. and 2000 California State MICRO Grant 00-032. 4 Sr. automation engineer, TMG, Intel Corp., 2501 NW 229 Street, Hillsboro, OR 97124. Former postdoctoral researcher in ALPHA Lab. Abstract Semiconductor manufacturing industry requires highly accurate robot operation with short downtime. We develop a fast, low cost and easy-to-operate cali...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Robotics Society of Japan
سال: 1997
ISSN: 0289-1824,1884-7145