Robotic-arm assisted total hip arthroplasty

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of Component Placement in Robotic-Assisted Total Hip Arthroplasty.

Robotic-assisted total hip arthroplasty (THA) is a recent platform introduced to decrease the risk of malpositioned components. The goals of this study were to determine whether intraoperative data on robotic-assisted THA acetabular component position accurately predict postoperative radiographic acetabular component position and to determine whether intraoperative data on robotic-assisted THA ...

متن کامل

Predictive value of robotic-assisted total hip arthroplasty.

Acetabular cup positioning, leg-length discrepancy, and global offset are important parameters associated with outcomes following total hip arthroplasty (THA). Deviation from an accepted range of values can lead to significant complications, including dislocation, leg-length discrepancy, impingement, accelerated bearing surface wear, and revisions. The purpose of this study was to assess whethe...

متن کامل

Robotic arm-assisted versus conventional unicompartmental knee arthroplasty

OBJECTIVES This study reports on a secondary exploratory analysis of the early clinical outcomes of a randomised clinical trial comparing robotic arm-assisted unicompartmental knee arthroplasty (UKA) for medial compartment osteoarthritis of the knee with manual UKA performed using traditional surgical jigs. This follows reporting of the primary outcomes of implant accuracy and gait analysis tha...

متن کامل

Computer-Assisted Orthopaedic Surgery and Robotic Surgery in Total Hip Arthroplasty

Various systems of computer-assisted orthopaedic surgery (CAOS) in total hip arthroplasty (THA) were reviewed. The first clinically applied system was an active robotic system (ROBODOC), which performed femoral implant cavity preparation as programmed preoperatively. Several reports on cementless THA with ROBODOC showed better stem alignment and less variance in limb-length inequality on radiog...

متن کامل

A comparison between robotic-assisted and manual implantation of cementless total hip arthroplasty.

BACKGROUND The benefits of robotic techniques for implanting femoral components during THA are still controversial. QUESTIONS/PURPOSES The purpose of this study was to prospectively compare the results and complications of robotic-assisted and hand-rasping stem implantation techniques. METHOD The minimum followup was 5 years (mean, 67 months; range, 60-85 months). One hundred forty-six prim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Annals of Translational Medicine

سال: 2018

ISSN: 2305-5839,2305-5847

DOI: 10.21037/atm.2018.10.37