Robotic partial nephrectomy with selective parenchymal compression (Simon clamp).
OBJECTIVE To present our initial experience using selective renal parenchymal ischemia, without hilar clamping, in robotic-assisted partial nephrectomy. MATERIAL AND METHODS In four patients with T1a renal tumor we performed robotic-assisted partial nephrectomy, using the Simon's clamp (Aesculap). It provides selective parenchymal compression without the need of vascular clamping. All patient...
متن کاملPartial clamping of the renal artery during robot-assisted laparoscopic partial nephrectomy: technique and initial outcomes.
PURPOSE We describe the feasibility of partial arterial clamping (PAC) during robot-assisted partial nephrectomy (RAPN). PATIENTS AND METHODS We undertook a retrospective study of five patients who underwent PAC vs 17 who underwent complete hilar clamping (CHC). Estimated blood loss (EBL), transfusion rate, operative/console time, warm ischemia time (WIT), pathology, and postoperative glomeru...
متن کاملRobotic Partial Nephrectomy Using Robotic Bulldog Clamps
BACKGROUND AND OBJECTIVES The need for a skilled assistant to perform hilar clamping during robotic partial nephrectomy is a potential limitation of the technique. We describe our experience using robotic bulldog clamps applied by the console surgeon for hilar clamping. METHODS A total of 60 consecutive patients underwent robotic partial nephrectomy, 30 using laparoscopic bulldog clamps appli...
متن کاملUsing a Harmonic Scalpel “Drilling and Clamping” Method to Implement Zero Ischemic Robotic-assisted Partial Nephrectomy
Robot-assisted partial nephrectomy (RAPN) has gradually become a popular minimally invasive nephron-sparing surgical option for small renal tumors. Ischemic injury should be minimized because it impacts renal function outcomes following partial nephrectomy. Herein, the authors detail the technique and present initial perioperative outcomes of our novel harmonic scalpel "drilling and clamping" m...