Robust Active Damping Control for LCL-Type Shunt Active Power Filters

نویسندگان

چکیده

A dual-loop current control is discussed for LCL -type shunt active power filters (APFs), where inverter-side feedback and point of common coupling (PCC) voltage feedforward both provide damping (AD) effects resonance. However, two ADs are equivalently applied to different elements filter with narrow boundaries, which causes less robustness against grid impedance variation. Hence, this paper has presented a comprehensive approach strengthen the system On basis phase compensated resonant unit, delay-compensation scheme firstly proposed extend boundary up almost Nyquist frequency ( $f_{s}/2$ ). Theory analysis considering PCC indicates that can keep robust when initial resonance falls between notation="LaTeX">$f_{s}/3$ extended boundary. Moreover, typical weighted proportional-resonant suggested prevent high-frequency units from inducing instability under large impedance. We finally validate effectiveness through experiments.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach

This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...

متن کامل

Adaptive Nonlinear Control of Three-Phase Shunt Active Power Filters

The problem of controlling three-phase shunt active power filters (SAPF) is addressed in presence of nonlinear loads supplied with three-phase power grids. The SAPF-load system is shown to be modeled, in the ( , ) coordinate frame, by a third-order nonlinear state-space representation. The control objective is twofold: (i) compensating for the current harmonics and the reactive power absorbed b...

متن کامل

Applicability improvement and hysteresis current control method simplification in shunt active filters

Hysteresis current control method is vastly used in PWM inverters because of simplicity in performance, fast control response and good ability in limiting peak current. However, switching frequency in hysteresis current control method with fixed bandwidth has large variation during a cycle and therefore causes non-optimal current ripple generation in output current. One of basic problems in imp...

متن کامل

Interval Type-2 Fuzzy Control of Shunt Active Power Filter

This paper proposes a new adaptive control technique for shunt active power filter (SAPF) by applying the interval type-2 fuzzy controller (IT2FC) in the DC voltage outer loop. This adaptive method achieved the main control objectives and compensated the active filter parameters uncertainties besides the unbalanced loads compensation without neutral wire. The interval type-2 fuzzy controller (I...

متن کامل

a novel reference current calculation method for shunt active power filters using a recursive algebraic approach

this paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (sapfs). this method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. next, the amplitude of the reference mains currentis computed with ...