Robust multipoint water-fat separation using fat likelihood analysis

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robust Multicoil Reconstruction for Phase-Sensitive Fat-Water Separation

Introduction: Phase-sensitive (PS) SSFP [1,2] is an efficient fat/water separation method, successfully used in several applications including angiography [1], musculoskeletal [3] and abdominal [4] imaging. It generates and detects a 180 phase-difference between fat and water. In previous work, water images reconstructed from individual coils with PSSSFP were combined [4,5]. However, abrupt spa...

متن کامل

Single-image water/fat separation

Introduction In MRI, fat can be hard to distinguish visually from pathology or contrast agent, due to its high signal intensity in many imaging sequences. Water and fat separation techniques provide an alternative to conventional fat suppression, and are also of interest in body composition applications. Dixon techniques [1] utilize the property of chemical shift to separate water and fat with ...

متن کامل

Water/Fat Separation MR Improves Optical Breast Imaging MR Water/Fat Separation Improves Optical Breast Imaging

Background Optical imaging may be added to MR mammography to provide absolute concentration images of oxygenated and deoxygenated hemoglobin, water, and other endogenous and exogenous molecular agents. This is beneficial because hemoglobin and tissue oxygenation have been shown in several studies to have high specificity to breast cancer [1]. This combined optical/MR instrument has been shown t...

متن کامل

Rapid MR imaging of articular cartilage with steady-state free precession and multipoint fat-water separation.

OBJECTIVE To obtain high-quality high-resolution images of articular cartilage with reduced imaging time, we combined a novel technique of generalized multipoint fat-water separation with three-dimensional (3D) steady-state free precession (SSFP) imaging. SUBJECTS AND METHODS The cartilage of 10 knees in five healthy volunteers was imaged with 3D SSFP imaging and a multipoint fat-water separa...

متن کامل

Robust water/fat separation in the presence of large field inhomogeneities using a graph cut algorithm.

Water/fat separation is a classical problem for in vivo proton MRI. Although many methods have been proposed to address this problem, robust water/fat separation remains a challenge, especially in the presence of large amplitude of static field inhomogeneities. This problem is challenging because of the nonuniqueness of the solution for an isolated voxel. This paper tackles the problem using a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2011

ISSN: 0740-3194

DOI: 10.1002/mrm.23087